Difference between revisions of "Qweak Elastic GEM Profile"

From New IAC Wiki
Jump to navigation Jump to search
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
Elastic electron scattering profile at Z=-528 and Z=-558, the two limits of the GEM keep out zone.
 
Elastic electron scattering profile at Z=-528 and Z=-558, the two limits of the GEM keep out zone.
  
Z target = -650 cm
+
the 35 cm target is at Z = -650 cm
If <math>\theta = </math> 6 degrees and Z = 72 + 50 = 122 cm then Y = 12.8 cm
 
  
 +
If <math>\theta = </math> 6 degrees and Z = -528-(-650)+35/2 = 139.5 cm then Y = Z \tan(6) =14.6 cm
  
If <math>\theta =</math> 11 degrees and Z = 72 + 50 = 122 cm
+
If <math>\theta = </math> 6 degrees and Z = -558-(-650)-35/2 = 74.5 cm then Y = Z \tan(6) = 7.8 cm
 +
 
 +
 
 +
IIf <math>\theta = </math> 11 degrees and Z = -528-(-650)+35/2 = 139.5 cm then Y = Z \tan(11) =27.12 cm
 +
 
 +
If <math>\theta = </math> 11 degrees and Z = -558-(-650)-35/2 = 74.5 cm then Y = Z \tan(11) = 14.48 cm
 +
 
 +
; GEM detector would need to span from 7.8 cm to 27.12 cm to catch elastic electrons which hit a scintillator moved 6 cm radially out from its present location.
  
 
Profiles generated by Neven using Katherine's Euclid file ([[Media:qweak_gw_5-dec-07.euclid.txt]])  representing the collimator design dated 8/8/07 from [http://www.iac.isu.edu/mediawiki/index.php/Collimator Paulo's Drawing "Hall -V QWEAK EXPERIMENT COLLIMATOR BUNKER SETUP UPSTREAM CLEANUP COLLIMATOR" # 67503-E-00021].
 
Profiles generated by Neven using Katherine's Euclid file ([[Media:qweak_gw_5-dec-07.euclid.txt]])  representing the collimator design dated 8/8/07 from [http://www.iac.isu.edu/mediawiki/index.php/Collimator Paulo's Drawing "Hall -V QWEAK EXPERIMENT COLLIMATOR BUNKER SETUP UPSTREAM CLEANUP COLLIMATOR" # 67503-E-00021].
Line 19: Line 26:
 
The electron profile closest to the beam pipe center appears to be about 8 cm away from the beam pipe center now instead of about 7.5 cm.
 
The electron profile closest to the beam pipe center appears to be about 8 cm away from the beam pipe center now instead of about 7.5 cm.
  
[http://www.iac.isu.edu/mediawiki/index.php/Qweak Go Back]
+
[[File:Qweak_E-coincidenceProfile.gif]]
 +
 
 +
[http://wiki.iac.isu.edu/mediawiki/index.php/Qweak Go Back][[Qweak]]

Latest revision as of 20:03, 13 November 2010

Elastic electron scattering profile at Z=-528 and Z=-558, the two limits of the GEM keep out zone.

the 35 cm target is at Z = -650 cm

If [math]\theta = [/math] 6 degrees and Z = -528-(-650)+35/2 = 139.5 cm then Y = Z \tan(6) =14.6 cm

If [math]\theta = [/math] 6 degrees and Z = -558-(-650)-35/2 = 74.5 cm then Y = Z \tan(6) = 7.8 cm


IIf [math]\theta = [/math] 11 degrees and Z = -528-(-650)+35/2 = 139.5 cm then Y = Z \tan(11) =27.12 cm

If [math]\theta = [/math] 11 degrees and Z = -558-(-650)-35/2 = 74.5 cm then Y = Z \tan(11) = 14.48 cm

GEM detector would need to span from 7.8 cm to 27.12 cm to catch elastic electrons which hit a scintillator moved 6 cm radially out from its present location.

Profiles generated by Neven using Katherine's Euclid file (Media:qweak_gw_5-dec-07.euclid.txt) representing the collimator design dated 8/8/07 from Paulo's Drawing "Hall -V QWEAK EXPERIMENT COLLIMATOR BUNKER SETUP UPSTREAM CLEANUP COLLIMATOR" # 67503-E-00021.


Qweak E-profile Z=-528 12-07.jpg Qweak E-profile Z=-558 12-07.jpg

The previous profiles prior to this latest change in the collimator when overlayed on top of each other looked like:

Qweak E-profile 2006.gif

The electron profile closest to the beam pipe center appears to be about 8 cm away from the beam pipe center now instead of about 7.5 cm.

Qweak E-coincidenceProfile.gif

Go BackQweak