Paste painting procedure

From New IAC Wiki
Jump to navigation Jump to search

Purpose

This document description the application proceedures to safely apply the ED-7100 carbon paste.

Requirements for safe handling

Before opening the paste please read the ED-7100 Safety Data Sheet located at

http://wiki.iac.isu.edu/index.php/File:ED7100_OSHA_MSDS.pdf

Be sure that the following are available:

Ventilation

An externally venting fume hood is recommended when working with this paste or a work area with very good ventilation.

Poor Ventilation area

Wear a well fitted NIOSH approved or industrial type canister mask.

http://www1.mscdirect.com/CGI/NNSRIT?PMPXNO=1651332&PMT4NO=0
http://www1.mscdirect.com/Disposable-Respirators-And-Masks/Respiratory-Protection/Safety/s0000002069.HTML


The following are required for applying the paste
  1. Gloves,goggles.
  2. suitable protection clothes.
  3. sack of sand or absorber for cleaning the area.

Paste Application Procedure

a- Review the "Requirements for Safe Handling" section preceding this one before using the paste.[1]
b- Equipment And Tools
  1. ED-7100 paste
  2. isobutanol for cleaning,
  3. CLR A/F lens blue frame revolution dust goggles
  4. 27"WD 36"L vinyl clear ansell chem-resist apron
  5. 35"WD 45"L neoprene Black ansell chem-resist apron
  6. 8511 N90 3M particulate respirator
  7. Nitrile disposal gloves


d- Application steps
  1. put on mask and apron (use goggles if spraying paste using printer)
  2. establish a work area under the ventilatin hood in the Laboratory for Detector Science#Add the paste to copper plate.(using a brush or a semi-mechanical printer)
  3. mix paste (if reducing is needed) under the hood for sufficient ventilation
  4. use applicator to smear paste on pc-board
  5. Clean the paste residues using isobutanol cleaner.
  6. Cure for 1 - 2h 30min. at 150 - 165 degrees Celsius.(Contact the company for IR-curing)


Back to the main page [2]