OptiM32 HRRL PositronDesign

From New IAC Wiki
Jump to navigation Jump to search

Software

Optim32 beamline design software

http://www-bdnew.fnal.gov/pbar/organizationalchart/lebedev/OptiM/optim.htm


G4Beamline

http://www.muonsinc.com/tiki-index.php?page=G4beamline


Quick Start

The instruction below assume you have successfully installed the software above.

Creat the *.in files

On the windows machine you can open the file below which represent one design for the HRRL positron source

File:Optim32 HRRL Design Script V1.0.txt

save the above file as HRRL.opt.

The launch the Optim executable by double clicking.

After it is launched click on the "file" menu in the GUI and select the "Open" menu item to choose the file HRRL.opt.

After it is loaded you should see the following below.

Optim QS Step1.png


If you click on the icon with the [math]\beta \psi[/math] symbols (9th button from the end of the tool bar) you can get a plot of the beam dispersion

Optim QS Step2.png


This is an interactive display. You can adjust values in the loaded text vile and watch their effect on the dispersion. Notice the colored rectangles at the colored rectangles at the bottom of the beta curve sub window. Starting from the left bottom there are 3 read rectangles , a blue rectangle, then 3 red rectangles, a blue rectangle, and finally 3 more red rectangles. The red rectangles are the quadrupoles in the beam line and the blue rectangles are the dipoles. If you click on them their element name will appear in the upper right corner of the dispersion sub window.

If you scroll down the HRRL.opt input file to line which says

begin list

you will se a list of all the elements, the B-field values, their lengths, etc...

If you scroll down to the first quad

q0 	L[cm]=13         	G[kG/cm]=0.0438324 	Tilt[deg]=0

you can move the curser the the B-field value "G[kG/cm]=0.0438324" and increment it while watch the effect on the dispersion plot. You increments it hitting the left and right arrow keys while holding down the "Crtl" key. The value of the increment step is controlled by through the parameters available in the dialog box you get when you select "Steps" from the "Edit" menu.

Optim QS Step3.png

The above says the quadrupole B-field step size is set to 0.005.