<math>\sigma_{pair_production} = 0.5 </math>

Revision as of 05:13, 18 January 2011

Go Back

LINAC parameters used in calculations

1) pulse width 50 ps
2) pulse current 50 A
3) repetition rate 300 Hz
4) energy 44 MeV

Number of electrons/sec on radiator

[math] 50\ \frac{Coulomb}{sec} \times \frac{1\cdot e^-}{1.6\cdot 10^{-19}C} \times 50ps \times 300Hz = 4.68 \cdot 10^{12} \frac{e^-}{sec}[/math]

Number of photons/sec out of radiator

[math]\sigma_{brems}=0.1 photons/electrons/MeV/r.l[/math]
r.l.(Ti) = 3.59 cm
  
radiator thickness = 12.5 [math]\mu m[/math]
[math]\frac{12.5\ \mu m}{3.59\ cm} = 3.48 \cdot 10^{-4} \ r.l.[/math]
[math]0.1\ \frac{\gamma 's}{(e^- \cdot MeV \cdot r.l.)} \times 3.48 \cdot 10^{-4} r.l. \times 10\ MeV \times 0.47 \cdot 10^{13} \frac{e^-}{sec}=1.63 \cdot 10^{9} \frac{\gamma}{sec}[/math]

Alex factor is 6.85 %
[math]1.64 \cdot 10^{9} \frac{\gamma}{sec} \cdot 6.85\ % = 1.12 \cdot 10^{8} \frac{\gamma}{sec}[/math]

Number of electron/positron pairs/sec out of Al converter

[math]\sigma_{pair_production} = 0.5 [/math]