Difference between revisions of "Neutron scattering in lead shielding"

From New IAC Wiki
Jump to navigation Jump to search
 
(11 intermediate revisions by the same user not shown)
Line 2: Line 2:
  
  
 +
Source neutrons are generated with MCNP-POLIMI CF252 SF generator. The detector is 1.25 meters from the source and the shielding geometry is shown below. The X-axis in the histogram is a distance between 2 points, namely: p1) Linearly extrapolating the neutron's initial direction of travel to intersect with the plane of the detector, and p2) the "actual" location in which the neutron deposited >=0.25 MeV of energy into the scintillator. The result is that on average the shielding scatters the neutrons by only 1".
  
 +
[[File:DetGeom.png|600px]]
  
 +
[[File:NDeflection.png|770px]]
  
  

Latest revision as of 22:47, 8 March 2017

go back MCNP simulations


Source neutrons are generated with MCNP-POLIMI CF252 SF generator. The detector is 1.25 meters from the source and the shielding geometry is shown below. The X-axis in the histogram is a distance between 2 points, namely: p1) Linearly extrapolating the neutron's initial direction of travel to intersect with the plane of the detector, and p2) the "actual" location in which the neutron deposited >=0.25 MeV of energy into the scintillator. The result is that on average the shielding scatters the neutrons by only 1".

DetGeom.png

NDeflection.png




go back MCNP simulations