Difference between revisions of "MiniPrototype SinglesCosmicRuns 2008"

From New IAC Wiki
Jump to navigation Jump to search
Line 249: Line 249:
 
|-  
 
|-  
 
| 150 ||  1667 || 1620 || 150 || 3244 || 100 || 16064 || 2184
 
| 150 ||  1667 || 1620 || 150 || 3244 || 100 || 16064 || 2184
 +
|-
 +
| 200 ||  ||  ||  || 200 ||  || 150 ||  || 
 
|-
 
|-
 
|}<br>
 
|}<br>
  
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#Cosmic_runs Go Back]
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#Cosmic_runs Go Back]

Revision as of 11:14, 21 May 2008

Goal

Use singles Cosmic events to measure rate differences between Metalica and Plastica

Apparatus

  • Plastica and Metalica are stacked on top of each other. High Voltage and ionization gas are connected in parallel.
  • A discriminator is connector to the amplified output (an on board preamp and the VPI Post amp) of sense wire 4.
  • The discriminator output is connected to a VME scaler.

Proposed Tests

  1. Measure the singles rate as a function of DC high voltage
  2. Measure the singles rate as a function of Discriminator Threshold


9-05-2008

The DC high voltage is on. The DC outputs of Plastika and Metalica from sense wire 4 are connected to the Model 777 Octal Variable Gain Amplifier.

HV settings
Wire Volts
Sense 1450
Field -725
Guard 725


Scope picture below shows the Noise level on the DC measured in infinite persist time mode.
300px

Scope pictures representing the cosmic signals from Plastika and Metalica(Amplifier is connected)

  • Plastika

Plastika output wire 4 amplifier HV on 1450V 9-05-2008 1.png
Plastika output wire 4 amplifier HV on 1450V 9-05-2008 2.png
Plastika output wire 4 amplifier HV on 1450V 9-05-2008 3.png

  • Metalica

Metalica output wire 4 amplifier HV on 1450V 9-05-2008 1.png
Metalica output wire 4 amplifier HV on 1450V 9-05-2008 2.png
Metalica output wire 4 amplifier HV on 1450V 9-05-2008 3.png

Rate -vs- Discriminator Threshold

Gas is ArCo2 . 75/25 mixture

HV settings
Wire Volts
Sense 1700
Field -850
Guard 850


Threshold (mV) Metalica (Events/hr) Plastika (Events/hr) Coincidence
300 701 [math]\pm \sqrt{\frac{1.04194}{730}}[/math] 627 [math]\pm \sqrt{\frac{1.04194}{653}}[/math]
300 560 [math]\pm \sqrt{\frac{1.01639}{569}}[/math] 570 [math]\pm \sqrt{\frac{1.01639}{579}}[/math]
310 [math]592 \pm 11[/math] [math]500 \pm 24[/math]
325 [math]528 \pm 65[/math] [math]465 \pm 30[/math] 32
350 [math]421 \pm 48[/math] [math]379 \pm 40[/math]
400 [math]305[/math] [math]235[/math] 31


Gas is ArCo2 . 90/10 mixture

HV settings
Wire Volts
Sense 1450
Field -725
Guard 725


The scope picture below was taken to illustrate the noise levels on the DC signals after amplification just before disrimination. Previous measurements suggested that the sense wire signal noise had an RMS of about 10 mV. The phillips amplifier doubles this noise RMS. The amplitude of the noise is about 30 mV.


BabyChamberAfterPhillipsAmp 5-12-08.png

Threshold (mV) Metalica (Events/hr) Plastika (Events/hr) Coincidence (Event/hr)
100 1915 1912 90
100 2148 1799 36
100 1885 1758 37
100 2012 1912 91
100 1905 1754 25
150 671 588 14
150 645 596 11
150 634 596 19
150 629 563 13
150 634 550 5
175 361 358 20
175 380 329 14
175 396 329 14
175 391 344 10
200 286 256 25
200 291 232 4
200 291 251 6
225 183 168 4
225 193 180 6
250 122 120 2
300 93 88 2
350 74 60 3


Threshold (mV) Metalica (Events/hr) Plastika (Events/hr) Coincidence (Event/hr)
100 [math]1973 \pm 98[/math] [math]1827 \pm 71[/math]
150 [math]643 \pm 15[/math] [math]583 \pm 17[/math]
175 [math]382 \pm 13[/math] [math]340 \pm 12[/math]
200 [math]289 \pm 2[/math] [math]246 \pm 10[/math]
225 [math]188 \pm 5[/math] [math]174 \pm 6[/math]
250 122 120
300 93 88
350 74 60


With preamp and Post amp on

Sense wire #4 from Metalica comes out of VPI post amp channel #10. VPI channel #15 goes into ADC channel #3


Sense wire #4 from Plastika comes out of VPI post amp channel #15. VPI channel #15 goes into ADC channel #6

Voltage on preamp is 6.0 V.

HV settings
Wire Volts
Sense 1500
Field -750
Guard 750



Compare Phillips output and VPI postamp output

Noise level of Plastika and Metalica. The moise on the Phillips amp went from 10 mV to 100 mV due to the voltage applied to the preamps. If you turn the preamp power supply off the noise will go back to ~20 mV.
Plastika
Plastika noise level after VPIPostAmp and Phillips777 amplifier.png
Metalica
Metalica noise level after VPIPostAmp and Phillips777 amplifier.png

Plastika phillips output vs VPI postamp output HV on 1500 1.pngPlastika phillips output vs VPI postamp output HV on 1500 2.png
Metalica phillips output vs VPI postamp output HV on 1500 1.pngMetalica phillips output vs VPI postamp output HV on 1500 2.png

Threshold Phillips777(mV) Metalica (Events/hr) Plastika (Events/hr) Threshold VPI PostAmp(mV) Metalica (Events/hr) Plastika (Events/hr)
300 143 144 1000 245 160
300 150 145 1000 223 153


16-05-2008

HV settings
Wire Volts
Sense 1500
Field -750
Guard 750


The Voltage on the PreAmp is 6.3 Volts

Metalica
Metalica noise level after VPIPostAmp and Phillips777 amplifier preamp 6 3V.png
Plastika
Plastika noise level after VPIPostAmp and Phillips777 amplifier preamp 6 3V.png

Metalica signal output after VPIPostAmp and Phillips777 amplifier preamp 6 6V.png

The first one is just one hour run.

Threshold Phillips777(mV) Metalica (Events/hr) Plastika (Events/hr) Threshold VPI PostAmp(mV) Metalica (Events/hr) Threshold VPI PostAmp(mV) Plastika (Events/hr) time
250 287 287 350 176 350 171
250 294 298 350 183 350 178
250 303 297 350 187 350 178
150 1126 1078 150 2141 100 9840 2623
150 1283 1388 150 2683 100 12753 2141
150 1667 1620 150 3244 100 16064 2184
200 200 150


Go Back