Difference between revisions of "MiniPrototype SinglesCosmicRuns 2008"

From New IAC Wiki
Jump to navigation Jump to search
Line 15: Line 15:
  
 
The DC high voltage is '''on'''. The DC outputs of Plastika and Metalica from sense wire 3 are connected to the Model 777 Octal Variable Gain Amplifier.<br>
 
The DC high voltage is '''on'''. The DC outputs of Plastika and Metalica from sense wire 3 are connected to the Model 777 Octal Variable Gain Amplifier.<br>
 
+
{| border="1"  |cellpadding="20" cellspacing="0
 +
|colspan= "3" | HV settings
 +
|-
 +
| Wire ||  Volts
 +
|-
 +
|Sense ||  1700
 +
|-
 +
|Field ||  -800 
 +
|-
 +
|Guard ||  800
 +
|}
  
  
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#Cosmic_runs Go Back]
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#Cosmic_runs Go Back]

Revision as of 04:49, 1 May 2008

Goal

Use singles Cosmic events to measure rate differences between Metalica and Plastica

Apparatus

  • Plastica and Metalica are stacked on top of each other. High Voltage and ionization gas are connected in parallel.
  • A discriminator is connector to the amplified output (an on board preamp and the VPI Post amp) of sense wire 4.
  • The discriminator output is connected to a VME scaler.

Proposed Tests

  1. Measure the singles rate as a function of DC high voltage
  2. Measure the singles rate as a function of Discriminator Threshold


30-04-2008

The DC high voltage is on. The DC outputs of Plastika and Metalica from sense wire 3 are connected to the Model 777 Octal Variable Gain Amplifier.

HV settings
Wire Volts
Sense 1700
Field -800
Guard 800


Go Back