Difference between revisions of "MiniPrototype SinglesCosmicRuns 2008"

From New IAC Wiki
Jump to navigation Jump to search
Line 46: Line 46:
 
::Discriminator Threshold=450MV
 
::Discriminator Threshold=450MV
 
[[Image:plastika_output_wire_3_amplifier_discriminator_HV_on_1800V_30-04-2008_1.png|300px]]<br>
 
[[Image:plastika_output_wire_3_amplifier_discriminator_HV_on_1800V_30-04-2008_1.png|300px]]<br>
 +
 +
=Rate -vs- Discriminator Threshold=
 +
 +
{| border="1"  |cellpadding="20" cellspacing="0
 +
|colspan= "3" | HV settings
 +
|-
 +
| Wire ||  Volts
 +
|-
 +
|Sense ||  1700
 +
|-
 +
|Field ||  -850 
 +
|-
 +
|Guard ||  850
 +
|}<br>
 +
 +
{| border="1"  |cellpadding="20" cellspacing="0
 +
|-
 +
|Threshold (mv) ||  Metalica (Events/hr) || plastica (Events/hr)
 +
|-
 +
|400 ||  130504 <math>\pm \sqrt(2153324)</math>    || 3440 <math>\pm \sqrt(56758)</math>
 +
|-
 +
|}<br>
 +
 +
 +
  
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#Cosmic_runs Go Back]
 
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#Cosmic_runs Go Back]

Revision as of 16:41, 2 May 2008

Goal

Use singles Cosmic events to measure rate differences between Metalica and Plastica

Apparatus

  • Plastica and Metalica are stacked on top of each other. High Voltage and ionization gas are connected in parallel.
  • A discriminator is connector to the amplified output (an on board preamp and the VPI Post amp) of sense wire 4.
  • The discriminator output is connected to a VME scaler.

Proposed Tests

  1. Measure the singles rate as a function of DC high voltage
  2. Measure the singles rate as a function of Discriminator Threshold


30-04-2008

The DC high voltage is on. The DC outputs of Plastika and Metalica from sense wire 3 are connected to the Model 777 Octal Variable Gain Amplifier.

HV settings
Wire Volts
Sense 1700
Field -800
Guard 800


Scope picture below shows the Noise level on the DC measured in infinite persist time mode.
Noise level of plastika and metalica using gain amplifier 30-04-2008.png

Scope pictures representing the cosmic signals from Plastika and Metalica(Amplifier is connected)

  • Plastika

Plastika output wire 3 amplifier HV on 1800V 30-04-2008 1.png
Plastika output wire 3 amplifier HV on 1800V 30-04-2008 2.png
Plastika output wire 3 amplifier HV on 1800V 30-04-2008 3.png

  • Metalica

Metalica output wire 3 amplifier HV on 1800V 30-04-2008 1.png
Metalica output wire 3 amplifier HV on 1800V 30-04-2008 2.png
Metalica output wire 3 amplifier HV on 1800V 30-04-2008 3.png

OUTPUTS FROM DISCRIMINATOR

Discriminator Threshold=450MV

Plastika output wire 3 amplifier discriminator HV on 1800V 30-04-2008 1.png

Rate -vs- Discriminator Threshold

HV settings
Wire Volts
Sense 1700
Field -850
Guard 850


Threshold (mv) Metalica (Events/hr) plastica (Events/hr)
400 130504 [math]\pm \sqrt(2153324)[/math] 3440 [math]\pm \sqrt(56758)[/math]




Go Back