Difference between revisions of "MiniDC Signals 4-25-08"

From New IAC Wiki
Jump to navigation Jump to search
Line 28: Line 28:
 
=Without PreAmp cables=
 
=Without PreAmp cables=
  
HV is turned off. PreAmp is not connected to the DC(M&P).(ground on sense wire 4 (M&P))<br>
+
HV is turned off. PreAmp cables are not connected to the DC(M&P).(ground on sense wire 4 (M&P))<br>
  
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4.png|300px]]<br>
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4.png|300px]]<br>
Line 34: Line 34:
  
  
HV is turned off. PreAmp is not connected to the DC(M&P).<br>
+
HV is turned off. PreAmp cables are not connected to the DC(M&P).<br>
  
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground.png|300px]]<br>
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground.png|300px]]<br>
Line 40: Line 40:
  
  
HV is turned off. PreAmp is not connected to the DC(M&P).(ground on sense wire 4 (M))<br>
+
HV is turned off. PreAmp cables are not connected to the DC(M&P).(ground on sense wire 4 (M))<br>
  
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4_m.png|300px]]<br>
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4_m.png|300px]]<br>
Line 46: Line 46:
  
  
HV is turned off. PreAmp is not connected to the DC(M&P).(ground on sense wire 4 (P))<br>
+
HV is turned off. PreAmp cables are not connected to the DC(M&P).(ground on sense wire 4 (P))<br>
  
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4_p.png|300px]]<br>
 
[[Image:noise_level_on_plastika_and_metalica_HV_off_ground_on_sense_wire_4_p.png|300px]]<br>

Revision as of 18:07, 25 April 2008

PreAmp cables connected to DC

High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).(ground on sense wire 4(M&P))

Noise level on plastika and metalica PreAmp off cables connected HV off ground on sense wire 4.png


High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).(ground on sense wire 4(Plastika))

Noise level on plastika and metalica PreAmp off cables connected HV off ground on sense wire 4 P.png



High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).(ground on sense wire 4(Metalica))

Noise level on plastika and metalica PreAmp off cables connected HV off ground on sense wire 4 M.png


High voltage on sense wires and on PreAmp is turned off. The PreAmp cables are connected to the DC(Metalica and Plastika).

Noise level on plastika and metalica PreAmp off cables connected HV off.png

Without PreAmp cables

HV is turned off. PreAmp cables are not connected to the DC(M&P).(ground on sense wire 4 (M&P))

Noise level on plastika and metalica HV off ground on sense wire 4.png


HV is turned off. PreAmp cables are not connected to the DC(M&P).

Noise level on plastika and metalica HV off ground.png


HV is turned off. PreAmp cables are not connected to the DC(M&P).(ground on sense wire 4 (M))

Noise level on plastika and metalica HV off ground on sense wire 4 m.png


HV is turned off. PreAmp cables are not connected to the DC(M&P).(ground on sense wire 4 (P))

Noise level on plastika and metalica HV off ground on sense wire 4 p.png


G0 Back