PreAmp is turned off.<br>
 
PreAmp is turned off.<br>
  
 +
The left picture has Platika on Ch 1 the right picture swaps the cables between the scope and the sense wire.  Hence, Metalica is shown on Ch1 after swapping the leads.
 
{| border="1"  |cellpadding="20" cellspacing="0  
 
{| border="1"  |cellpadding="20" cellspacing="0  
 
|colspan= "3" | HV settings  
 
|colspan= "3" | HV settings  
Line 13: Line 14:
 
|}
 
|}
 
Noise:
 
Noise:
[[Image:BabyChamber_Noise_Wire4_HV_on_1500V_4-22-08.png | 400 px]][[Image:BabyChamber_NoiseWire4_HV_on_1500V_4-22-08_1.png | 400 px]]<br>
+
[[Image:BabyChamber_Noise_Wire4_HV_on_1500V_4-22-08.png | 200 px]][[Image:BabyChamber_NoiseWire4_HV_on_1500V_4-22-08_1.png | 200 px]]<br>
Signal:
+
 
[[Image:BabyChamber_Signal_Wire4_HV_on_1500V_4-22-08.png | 400 px]]
 
  
 
{| border="1"  |cellpadding="20" cellspacing="0  
 
{| border="1"  |cellpadding="20" cellspacing="0  
Line 29: Line 29:
 
|}
 
|}
 
Noise:
 
Noise:
[[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08.png | 400 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08_1.png | 400 px]]<br>
+
[[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08.png | 200 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1550V_4-22-08_1.png | 200 px]]<br>
Signal:
 
[[Image:BabyChamber_Signal_Wire4_HV_on_1550V_4-22-08.png | 400 px]][[Image:BabyChamber_Signal_Wire4_HV_on_1550V_4-22-08_1.png | 400 px]]<br>
 
  
 
{| border="1"  |cellpadding="20" cellspacing="0  
 
{| border="1"  |cellpadding="20" cellspacing="0  
Line 45: Line 43:
 
|}
 
|}
 
Noise:
 
Noise:
[[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08.png | 400 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08_1.png | 400 px]]<br>
+
[[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08.png | 200 px]][[Image:BabyChamber_Noise_Wire4_HV_on_1450V_4-22-08_1.png | 200 px]]<br>
Signal:
+
 
[[Image:BabyChamber_Signal_Wire4_HV_on_1450V_4-22-08.png | 400 px]]<br>
+
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype G0 Back]

Latest revision as of 17:33, 24 April 2008

PreAmp is turned off.

The left picture has Platika on Ch 1 the right picture swaps the cables between the scope and the sense wire. Hence, Metalica is shown on Ch1 after swapping the leads.

HV settings
Wire Volts
Sense 1500
Field -750
Guard 750

Noise: BabyChamber Noise Wire4 HV on 1500V 4-22-08.pngBabyChamber NoiseWire4 HV on 1500V 4-22-08 1.png


HV settings
Wire Volts
Sense 1550
Field -775
Guard 775

Noise: BabyChamber Noise Wire4 HV on 1550V 4-22-08.pngBabyChamber Noise Wire4 HV on 1550V 4-22-08 1.png

HV settings
Wire Volts
Sense 1450
Field -725
Guard 725

Noise: BabyChamber Noise Wire4 HV on 1450V 4-22-08.pngBabyChamber Noise Wire4 HV on 1450V 4-22-08 1.png

G0 Back