Difference between revisions of "Looking at effects of Solenoid on Phi Shifts"

From New IAC Wiki
Jump to navigation Jump to search
Line 6: Line 6:
  
 
<center>[[File:FinalTheta.jpg]]</center>
 
<center>[[File:FinalTheta.jpg]]</center>
<pre>
+
 
    Px=evt.FnlMom[0]/1000;
 
                Py=evt.FnlMom[1]/1000;
 
                Pz=evt.FnlMom[2]/1000;               
 
                px=evt.MolMom[0]/1000;
 
                py=evt.MolMom[1]/1000;
 
                pz=evt.MolMom[2]/1000;
 
               
 
                KE=evt.FnlKE/1000;
 
                ke=evt.MolKE/1000;
 
</pre>
 
 
Using the fact that the minimum momentum of MollerScattering_NH3_4e8incident.dat is about 2 MeV,
 
Using the fact that the minimum momentum of MollerScattering_NH3_4e8incident.dat is about 2 MeV,
  
Line 29: Line 19:
  
 
11000    0    0    11000.5    0    0    -510    5500.31    28.1338    -44.9298    5500.56    0    0    -506.13    5498.52    -28.1338    44.9298    5498.78    0    0    -506.13 </pre>
 
11000    0    0    11000.5    0    0    -510    5500.31    28.1338    -44.9298    5500.56    0    0    -506.13    5498.52    -28.1338    44.9298    5498.78    0    0    -506.13 </pre>
 +
 +
We can alter the lines
 +
<pre>
 +
    Px=evt.FnlMom[0]/1000;
 +
                Py=evt.FnlMom[1]/1000;
 +
                Pz=evt.FnlMom[2]/1000;               
 +
                px=evt.MolMom[0]/1000;
 +
                py=evt.MolMom[1]/1000;
 +
                pz=evt.MolMom[2]/1000;
 +
               
 +
                KE=evt.FnlKE/1000;
 +
                ke=evt.MolKE/1000;
 +
</pre>
  
 
Dividing by 1 will give us a distribution of 2GeV-5500 GeV.
 
Dividing by 1 will give us a distribution of 2GeV-5500 GeV.
Line 34: Line 37:
 
Divinding by 10 will give us a distribution of 0.2GeV-550 GeV
 
Divinding by 10 will give us a distribution of 0.2GeV-550 GeV
  
Dividing by 100 will give us a distribution of 0.02GeV-55GeV
+
Dividing by 100 will give us a distribution of 0.02GeV-55 GeV
  
 
=[[Solenoid_effect_in_ 2_GeV_and_up_range|Solenoid effect > 2GeV]]=
 
=[[Solenoid_effect_in_ 2_GeV_and_up_range|Solenoid effect > 2GeV]]=

Revision as of 22:42, 5 April 2016

Using Moller Data to alter energy range

Using the Moller event file MollerScattering_NH3_4e8incident.dat, we can use the fact that GEMC will only create a particle based on the Moller electron. While the data for the scattered electron is passed within a LUND file, kinematically this electron doesn't leave the beam area, and thus never enters the detectors to be recreated. Since the solenoid's purpose is draw electrons trajectories closer the the beam line any electron close the the beam line will be drawn even closer, ensuring that it is never recreated in a GEMC simulation.

We can alter the energy conversion from MollerScattering_NH3_4e8incident.dat to investigate the energy-phi shift relationship

FinalTheta.jpg

Using the fact that the minimum momentum of MollerScattering_NH3_4e8incident.dat is about 2 MeV,

awk 'NR == 1 {line = $0; min = $15} NR >1 && $15 < min {line =$0; min =$15} END{print line}' MollerScattering_NH3_4e8incident.dat

11000    0     0     11000.5     0     0     0     10997.9     1.42548     -0.177032     10998.4     0     0     0     2.01929     -1.42548     0.177032     2.01939     0     0     -509.621 

and the maximum of about 5500 MeV,

awk 'NR == 1 {line = $0; max = $15} NR >1 && $15 > max {line =$0; max =$15} END{print line}' MollerScattering_NH3_4e8incident.dat

11000    0     0     11000.5     0     0     -510     5500.31     28.1338     -44.9298     5500.56     0     0     -506.13     5498.52     -28.1338     44.9298     5498.78     0     0     -506.13 

We can alter the lines

    Px=evt.FnlMom[0]/1000;
                Py=evt.FnlMom[1]/1000;
                Pz=evt.FnlMom[2]/1000;                
                px=evt.MolMom[0]/1000;
                py=evt.MolMom[1]/1000;
                pz=evt.MolMom[2]/1000;
                
                KE=evt.FnlKE/1000;
                ke=evt.MolKE/1000;

Dividing by 1 will give us a distribution of 2GeV-5500 GeV.

Divinding by 10 will give us a distribution of 0.2GeV-550 GeV

Dividing by 100 will give us a distribution of 0.02GeV-55 GeV

Solenoid effect > 2GeV

Solenoid effect > 200 MeV

Solenoid effect > 20MeV


Links

Back