|The observed photon energy distributions as measured by the HpGe (top) and NaI (bottom) detectors.  There was no coincidence requirement using the two detectors. || The HpGe photon energy distribution before and after a sweep magnet is used to deflect charged particles away from the conversion target.  
 
|}
 
|}
  

Revision as of 22:31, 22 July 2013

Award Info

8/15/09 - 8/14/2012

Funds Obligated: $381,509

Funds Requested: $411,509

Sponsored Project Proposal Number : 8-17

DOE Award Number : DE-SC0002600

Accounts set up on 10/14/09

Banner Index : RACL39 Account Numer : 684-143-40

Fund: X10165, Org code: 640000, Program : 040R0

Final Report

DOE Award #: DE-SC0002600

Project Title: The Development of a Positron Source for JLab at the IAC

Date: 8/1/13

Period covered: 8/15/09-8/14/2013 (Final Report)

Accomplishments

The performance of positron source using a quad triplet collection system has been measured using the support from this award.

Initial Positron production measurement

An initial set of positron production efficiency measurements were performed


Chips run-2008 setup.png
The beam line used for an initial set of positron production measurements


Item Description
Tantalum Foil 6 mm thick 20 mm x 20 mm area
Tungsten Foil 2 mm thick 20 mm x 20 mm area
Phosphorus Flag 1 mil aluminum backing
Media:HpGe_Crystal_GEM-60195-Plus-P.pdf 81.3mm Diameter, 55.5mm Length
NaI detector
Run60 HpGe-NaI.gif PositronYield SweeperMagnet run60-61.gif
The observed photon energy distributions as measured by the HpGe (top) and NaI (bottom) detectors. There was no coincidence requirement using the two detectors. The HpGe photon energy distribution before and after a sweep magnet is used to deflect charged particles away from the conversion target.

2nd Generation positron source

BeamLine Yim 10-14-10.png
HRRL beamline for positron generation.