Difference between revisions of "JB Anaysis"

From New IAC Wiki
Jump to navigation Jump to search
 
(94 intermediate revisions by the same user not shown)
Line 1: Line 1:
=Run 4507=
+
Go back [[2nCor_44]]
==Neutron-Gamma Seperation==
+
=DU runs=
Detector 1
+
==TDC spectrum==
 +
[[DTC]]
  
[[file:Det1Seperationj.png| 500 px]]
+
==Target in vs. target out==
 +
Gamma peak is revealed by comparing target in and target out runs. 
 +
 
 +
[[File:Gammas(2).jpg | 950 px]]
 +
 
 +
[[2nCor_44#Analysis]]
 +
 
 +
==ToF==
 +
<math>Neutron TOF=\frac{PMT_{top}+PMT_{bottom}}{2}-t_{\gamma peak}+\gamma_{TOF}</math>
 +
[[File:Det4ToF.png| 500 px]]
 +
 
 +
==Energy==
 +
Neutron Energy:   
 +
 
 +
<math>\frac{1}{2}m_{n}\left(\frac{in}{ns}\right)^2=3.372\left(\frac{42}{t}\right)^2 MeV</math>
 +
 
 +
Watt distribution: 
 +
 
 +
<math>Ce^{-aE^'}\sinh\left(\sqrt{bE^'}\right)=0.708 e^{-0.884 E^'}\sinh \left(\sqrt{E^'}\right)</math>
 +
 
 +
[[File:Watt.jpg|1000 px]]
  
Detector 2
+
==Second Hit==
 +
Odd TDC spectrum in the second hit:
  
[[file:Det2TDC.png | 500 px]]
+
[[File:Snip20150815 28.png | 1110 px]]
  
Detector 3
+
Applying cuts based on TDC difference could help:
  
[[file:Det3PMT.png| 500 px]]
+
[[File:SecondHit.png|1000 px]]
  
Detector 4
+
==Opening angles==
 +
Uncorrelated distribution from detectors 1-4:
  
[[File:Det4TDC.png|500 px]]
+
[[File:Snip20150729 3.png|750 px]]
  
==Target in vs. target out==
+
Analyzing 5653446 pulses from DU runs, I was able to find 349 two-neutron events in detectors 1-4.
Gamma peak revealed by comparing two runs with and without target
+
 
(open the file to see it clearly)
+
[[File:CorrOverUncorR.png| 750 px]]
 +
 
 +
As a test I did the same for gamma events:
  
[[file:Det4Gammas.png| 700 px]]
+
[[File:Snip20150815 29.png| 500 px]]
  
[[2nCor_44#Analysis]]
 
  
==ToF & Energy==
+
Go back [[2nCor_44]]
[[File:Det4ToF.png| 700 px]]
 
[[File:DEt4NeutronEnergy.png| 700 px]]
 
[[File:EngvsWqatt.jpg | 700 px]]
 

Latest revision as of 23:10, 19 August 2015

Go back 2nCor_44

DU runs

TDC spectrum

DTC

Target in vs. target out

Gamma peak is revealed by comparing target in and target out runs.

Gammas(2).jpg

2nCor_44#Analysis

ToF

[math]Neutron TOF=\frac{PMT_{top}+PMT_{bottom}}{2}-t_{\gamma peak}+\gamma_{TOF}[/math] Det4ToF.png

Energy

Neutron Energy:

[math]\frac{1}{2}m_{n}\left(\frac{in}{ns}\right)^2=3.372\left(\frac{42}{t}\right)^2 MeV[/math]

Watt distribution:

[math]Ce^{-aE^'}\sinh\left(\sqrt{bE^'}\right)=0.708 e^{-0.884 E^'}\sinh \left(\sqrt{E^'}\right)[/math]

Watt.jpg

Second Hit

Odd TDC spectrum in the second hit:

Snip20150815 28.png

Applying cuts based on TDC difference could help:

SecondHit.png

Opening angles

Uncorrelated distribution from detectors 1-4:

Snip20150729 3.png

Analyzing 5653446 pulses from DU runs, I was able to find 349 two-neutron events in detectors 1-4.

CorrOverUncorR.png

As a test I did the same for gamma events:

Snip20150815 29.png


Go back 2nCor_44