MVME 6100
ROC1 ethernet address: 0001AF1998B5
ROC1 ethernet address: 0001AF1998B6
MPC7457 RISC G4 processor (PPC family)

Debug Connector Pinouts

Information below is Table 5-11 pg 92 of this reference

ROC Pin# DB9 Pin # Signal
1 1 DCD (Carrier Detect)
2 7 RTS (Request to Send)
3 5 GNDC
4 3 TX (Transmit)
5 2 RX (Recieve)
6 5 GNDC
7 8 CTS (Clear to Send)
8 4 DTR (Data Terminal Ready)

Basic commands

setting the time

The command below will print the help screen for the time set command

he set

for example

MVME6100> set -t082604163100
MVME6100> time
THU AUG 26 16:31:02.00 2004

show the flash memory

MVME6100> flashShow


Load in the VxWorks boot kernel

MVME6100> tftpGet -cCLIENT_IP_ADDRESS -sSERVER_IP_ADDRESS -fFILENAME

CLIENT_IP_ADDESS is the address to send the file to SERVER_IP_ADDRESS is the address of the computer hosting the file


Flash the RAM with the program

>MVME6100>flashProgram -d/dev/flash0 -o03f00100 -nfff00