HRRL Positrons Jul 2012 Runs Setup

From New IAC Wiki
Jump to navigation Jump to search

Targets

2 targets are from MIDWEST TUNGSTEN SERVICE.

0.040" x 1.50" x1.50". 99.95% Tungsten foils with four holes.

0.04" = 1.016 mm .

Materiel certification

Fe   0.0011%
Al   0.0010%
Ni   0.0010%
Si   0.0010%
C    0.0010%
N2   0.0020%
O2   0.0070%
W    99.95% minimum. 

File:CHIPs T1 TungstenTargetMatCert 0.8mm.pdf

T1 is placed with a vertical angle of 45 degree with respect to the beamline.

T2 is placed with vertical and horizantal angles of 45 degree with respect to the beamline.

T2 was switched from 2 mm target to 1 mm target [Switching Target].

Switching T2

Detectors setup

ADC inputs

Detector Left -> CH6

Detector Right -> CH5

Beam left Scintillator (between Q9 and Q10)-> CH9

Scintillator 1 (right next to the beam exit at the the 90 deg) -> CH2.

Battery -> CH13.

Note: There were some changes going on during the experiment. The above setup was according to the sent up on 27th of Jul. All the changes were recorded.

TDC input

According to the setup on 27th:

CH0->start from the gun.

CH1->95 ns delay of the start from gun.

CH5->NaI Left.

CH7->NaI Right.

13->Gate for signal (generated whenever there is a electron gun pulse, then fast cleared if there is no coincidence).

CH9-> discriminated output of NaI Left.

CH10-> discriminated output of NaI Right.

Scaler

The gun pulse connected to CH1 of the scaler . I thought I put it to CH0, may be somebody changed it.

HV power supply

We used 2CAEN Mod. N471 power supply. There are 2 of them. 2 for NaI and one for Scintilator1.

Power supply left, top channel-> NaI left

Power supply left, bottom channel-> NaI right

Power supply right, top channel-> Scintillator 1

Power supply on the Scintillator left and right was in HRRL cell. The voltage on them were 500 V.

Wiring

NaI dynode -->  474 Timing Amp (x20). (Dynode signal is weak.)
Timing Amp -->  8CH CFD (CAEN Mod. N842). (DL-THR = 31, DR-THR = 52.)
8CH CFD    -->  Octal Discriminator (PS model 710). (To use its veto to get rid off RF noise.)
Octal Dis  -->  Octalgate Generator (GG 8000-01). (To combine multi-pulses to a single wide pulse.)
Octalgate  -->  Quad coincidence (LeCroy model 622). (To generate AND logic between Gun and signal. 
                Logic is set as: (DL && GunTrig) && (DR && GunTrig) or (DL AND GunTrig) AND (DR AND GunTrig)  ).
Quad Coin  -->  Octalgate Generator (GG 8000-01). (To get better pulse.)
Octalgate  -->  ORTEC Gate & Delay Generator (416-06). (To create 6 micro-second delayed (from signal Gate) trigger )
Gate-Delay -->