HRRL Dec 20 2012Run

From New IAC Wiki
Jump to navigation Jump to search

3 MeV Spot on the Flag Tune

Beam is spread over the flag. Can not be focused.

Energy Switch Out (High En)
Solenoid 1 top 8.2 A
Solenoid 2 bottom 15.8 A
Gun Hor -0 A
Gun Ver -0.1 A
Output Hor -0.3 A
Output Ver +0 A
Rep Rate 300
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10 (Knob Setting)
RF frequency 2856.530 MHz
Modulator HV Power Supply 4.73 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) +0
Q2 (A) -0
Q3 (A) -0.6
Q4 (A) -0
Q5 (A) -0
Q6 (A) -0.8
D1 (A) 5.8
Q7 (A) -1.5
D2 (A) 5.8 (6.0 on shunt)
Q8 (A) 0
Q9 (A) -0
Q10 (A) -0
Steering coil at 90 deg beamline (A) 18 Amp
Current at FC0 3 mA

3 MeV Spot on the Flag plus 90 deg exit scintillator Tune

Scintilator blocked the beam spot. We see a darker area.

Energy Switch Out (High En)
Solenoid 1 top 6.9 A
Solenoid 2 bottom 15.3 A
Gun Hor -0 A
Gun Ver -0.1 A
Output Hor -0.3 A
Output Ver +0 A
Rep Rate 300
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10 (Knob Setting)
RF frequency 2856.530 MHz
Modulator HV Power Supply 4.73 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) +0
Q2 (A) -0
Q3 (A) -1.7
Q4 (A) -0
Q5 (A) -0
Q6 (A) -1
D1 (A) 5.8
Q7 (A) -2
D2 (A) 5.8 (6.0 on shunt)
Q8 (A) 0
Q9 (A) -0
Q10 (A) -0
Steering coil at 90 deg beamline (A) off
Current at FC0 3 mA