Difference between revisions of "HRRL 7-31-09"

From New IAC Wiki
Jump to navigation Jump to search
Line 107: Line 107:
  
  
We had several runs for different beam energy (2 && 4 MeV) and collimator size(~0.2 && ~0.8 cm).<br>
+
We had runs for different beam energy (2 && 4 MeV) and collimator size(~0.2 && ~0.8 cm).<br>
 
Table below shows TDC measurements for all cases for Metalica and Plastika.
 
Table below shows TDC measurements for all cases for Metalica and Plastika.
  
Line 127: Line 127:
 
| 1306 || 2 || 0.8 || 1400:-700:980 || 50 || [[File:TDCSpectrum_1306.gif|200px]][[File:TDCSpectrum_1306_1.gif|200px]]
 
| 1306 || 2 || 0.8 || 1400:-700:980 || 50 || [[File:TDCSpectrum_1306.gif|200px]][[File:TDCSpectrum_1306_1.gif|200px]]
 
|}
 
|}
 +
 +
[[File:HRRL_7-31-09_MetalicaPlastika_Start.png|250px]][[File:HRRL_7-31-09_MetalicaPlastika_Start_1.png|250px]]
  
 
=VFAT runs=
 
=VFAT runs=

Revision as of 05:29, 6 August 2009

Default HRRL running Conditions

[math]I_{peak}[/math] Pulse Width Rep Rate Energy
8 mA 100 ns 1 Hz 3 MeV


cable names

CH ID Description
2223A1 Front Scintillator
2223A2 Rear Scintilaltor
2223A3 ADC Gate From counting house to Experimental Cell
2223A4 TDC start pulse from counting house to experimental cell (PMT front + beam Gate)
2223A5 Coincidenc between front + rear Scint + Gun pulser to scaler channel 8
2223A6 Metalica sense wire 4
2223A7 Delayed rear PMT pulse to ADC
2223A8 Plastica sense wire 4
2223A9 Plastica to scaler channel 4
2223A10 Front scintillator to ADC
2223A11 Metalica scaler channel 1
2223A12 DAQ trigger


DAQ Ntuple names

Ntuple Variable Description
ADC5 Front Scintilator
ADC1 Metalica sense wire 4
ADC16 Rear Scintilator
ADC13 Plastica sense wire 4
TDC1 Metalica sense wire 4
TDC3 Plastika sense wire 4

ADC + Scaler + TDC + V1495

Run Number Distance to Metallica's Feedthrough tip (cm) Metalica scaler counts scaler ch 4 Plastika Scaler Counts scaler ch 1 Rear PMT + Front PMT + Gun Pulse Counts Scaler Ch 8 HV S:F:G Discriminator (mV) Metalica counts/PMT+Gun pulse
1263 19 0 1400:-700:980 50

TDC Measurements

TDC Calibration

Second pulse width is 80 ns.

Conclusion

In order to get actual time between the start and the stop pulse, one needs to subtract the width of the second signal. In this case it was 80 ns.

Run Number Scope Image TDC Histogram Calculated Time (ns) Time measured on the scope ns (between the fall of the first pulse and rise of the second pulse) Time measured on the scope ns (between the fall of the first pulse and fall of the second pulse)
1238 ImageTDCCalibration 1.png ImageTDCCalibration 1.gif 169.5 160 80
1239 ImageTDCCalibration 2.png ImageTDCCalibration 2.gif 135.7 130 50
1240 ImageTDCCalibration 3.png ImageTDCCalibration 3.gif 111.5 110 30


I need to do one more calibration run, which i think is gonna explain some things.

Actual Measurements

We had runs for different beam energy (2 && 4 MeV) and collimator size(~0.2 && ~0.8 cm).
Table below shows TDC measurements for all cases for Metalica and Plastika.

Run Number Beam Energy (MeV) Collimator size ~ (cm) HV S:F:G Discriminator Threshold (mV) TDC Histogram
1296 2 0.8 1400:-700:980 50 TDCSpectrum 1296.gifTDCSpectrum 1296 1.gif
1297, 1298 && 1299 4 0.8 1400:-700:980 50 TDCSpectrum 1297 8 9.gifTDCSpectrum 1297 8 9 1.gif
1304 && 1305 4 0.2 1400:-700:980 50 TDCSpectrum 1304-1305.gifTDCSpectrum 1304-1305 1.gif
1306 2 0.8 1400:-700:980 50 TDCSpectrum 1306.gifTDCSpectrum 1306 1.gif

HRRL 7-31-09 MetalicaPlastika Start.pngHRRL 7-31-09 MetalicaPlastika Start 1.png

VFAT runs

4 MeV beam energy, big collimator.

GEM HV settings: [math]V_{Drift}/V_{GEM}[/math]=3425/3125.

Run Number Card 1 Threshold Card 2 Threshold
1300 151 116
1301 153 118
1302 155 120
1303 157 122

GEM HV settings: [math]V_{Drift}/V_{GEM}[/math]=3425/3125.

4 MeV beam energy, small collimator.

Run Number Card 1 Threshold Card 2 Threshold
1305 151 124

File:Pb Attenuation Photon.pdf