HRRL 03-17-2011

From New IAC Wiki
Jump to navigation Jump to search

Accelerator Tuning

Good Tune Used for good Scan

By Dr. Kim

Solenoid 1 6.8 A
Solenoid 2 10.4 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -1.4A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.816 MHz
Modulator HV Power Supply 4.42 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns
Peak Current on FC 37.2 mAmps
Scope on FC Scope image of good Accelarator setting by Dr. Kim Mar 17 2011.png
e- Beam Energy 14 MeV



Calibration

image OTR image cal_h (mm/px) cal_v (mm/px)
HRRL 03-17-2011 cal 1 source.png HRRL 03-17-2011 cal 1.png 0.04308 0.04204
HRRL 03-17-2011 cal 2 source.png HRRL 03-17-2011 cal 2.png 0.04320 0.04228
HRRL 03-17-2011 cal 3 source.png HRRL 03-17-2011 cal 3.png 0.04349 0.04181
HRRL 03-17-2011 cal 4 source.png HRRL 03-17-2011 cal 4.png 0.04323 0.04196
HRRL 03-17-2011 cal 5 source.png HRRL 03-17-2011 cal 5.png 0.04337 0.04212
mean (mm/px) mean (mm/px)
[math] 0.04327 \pm 0.00016 [/math] [math] 0.04204 \pm 0.00018 [/math]


Results

Q1

42 mA, Positive Current, X projection

emit=0.375 +- 0.001 mm*mrad, emit_norm=10.263 +- 0.033 mm*mrad

beta=1.250 +- 0.000, alpha=0.936 +-0.001

HRRL 03-17-2011 Results Q1 42mA Pos X.png






HRRL_Emittance_Measurements_March14-18-2011