Difference between revisions of "HRRL 03-17-2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 43: Line 43:
  
 
{| border="3"  cellpadding="20" cellspacing="0"
 
{| border="3"  cellpadding="20" cellspacing="0"
| image || OTR image || Calibration
+
| image || OTR image || cal_h (mm/px) || cal_v (mm/px) ||
 
|-
 
|-
|[[File:HRRL_03-17-2011_cal_1_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_1.png | 200 px]]  ||
+
|[[File:HRRL_03-17-2011_cal_1_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_1.png | 200 px]]  ||    ||
 
|-
 
|-
|[[File:HRRL_03-17-2011_cal_2_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_2.png | 200 px]]  ||  
+
|[[File:HRRL_03-17-2011_cal_2_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_2.png | 200 px]]  ||    ||
 
|-
 
|-
|[[File:HRRL_03-17-2011_cal_3_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_3.png | 200 px]]  ||  
+
|[[File:HRRL_03-17-2011_cal_3_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_3.png | 200 px]]  ||    ||
 
|-
 
|-
|[[File:HRRL_03-17-2011_cal_4_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_4.png | 200 px]]  ||  
+
|[[File:HRRL_03-17-2011_cal_4_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_4.png | 200 px]]  ||    ||
 
|-
 
|-
|[[File:HRRL_03-17-2011_cal_5_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_5.png | 200 px]]  ||  
+
|[[File:HRRL_03-17-2011_cal_5_source.png | 200 px]]  || [[File:HRRL_03-17-2011_cal_5.png | 200 px]]  ||    ||
 +
|-
 +
|  || || mean (mm/px) || mean (mm/px) ||
 +
|-
 +
|  || || <math> 0.0 \pm 0.000 </math>||  <math> 0.0 \pm  0.000 </math> ||
 
|}
 
|}
  

Revision as of 04:53, 13 April 2011

Accelerator Tuning

Good Tune Used for good Scan

By Dr. Kim

Solenoid 1 6.8 A
Solenoid 2 10.4 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -1.4A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.816 MHz
Modulator HV Power Supply 4.42 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns
Peak Current on FC 37.2 mAmps
Scope on FC Scope image of good Accelarator setting by Dr. Kim Mar 17 2011.png
e- Beam Energy 14 MeV



Calibration

image OTR image cal_h (mm/px) cal_v (mm/px)
HRRL 03-17-2011 cal 1 source.png HRRL 03-17-2011 cal 1.png
HRRL 03-17-2011 cal 2 source.png HRRL 03-17-2011 cal 2.png
HRRL 03-17-2011 cal 3 source.png HRRL 03-17-2011 cal 3.png
HRRL 03-17-2011 cal 4 source.png HRRL 03-17-2011 cal 4.png
HRRL 03-17-2011 cal 5 source.png HRRL 03-17-2011 cal 5.png
mean (mm/px) mean (mm/px)
[math] 0.0 \pm 0.000 [/math] [math] 0.0 \pm 0.000 [/math]


cal_h (mm/px) cal_v (mm/px)
mean (mm/px) mean (mm/px)
[math] 0.0 \pm 0.000 [/math] [math] 0.0 \pm 0.000 [/math]







HRRL_Emittance_Measurements_March14-18-2011