Difference between revisions of "HRRL 03-15-2011"

From New IAC Wiki
Jump to navigation Jump to search
Line 23: Line 23:
 
===163mA===
 
===163mA===
 
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_x.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_x.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_x_Quad_Current.png | 300px]]
 +
  
 
x-projection:
 
x-projection:
Line 31: Line 33:
  
 
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_y.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_y.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_y_Quad_Current.png | 300px]]
 +
  
 
y-projection:
 
y-projection:
Line 40: Line 44:
 
===80mA===
 
===80mA===
 
[[File:HRRL_05-15-3011-Scan_Q1_80mA_Par_Fit_x.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_80mA_Par_Fit_x.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_80mA_Par_Fit_x_Quad_Current.png | 300px]]
 +
  
 
x-projection:
 
x-projection:
Line 49: Line 55:
  
 
[[File:HRRL_05-15-3011-Scan_Q1_80mA_Par_Fit_y.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_80mA_Par_Fit_y.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_80mA_Par_Fit_y_Quad_Current.png | 300px]]
 +
  
 
y-projection:
 
y-projection:
Line 60: Line 68:
 
===40mA===
 
===40mA===
 
[[File:HRRL_05-15-3011-Scan_Q1_40mA_Par_Fit_x.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_40mA_Par_Fit_x.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_40mA_Par_Fit_x_Quad_Current.png | 300px]]
 +
  
 
x-projection:
 
x-projection:
Line 72: Line 82:
  
 
[[File:HRRL_05-15-3011-Scan_Q1_40mA_Par_Fit_y.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_40mA_Par_Fit_y.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_40mA_Par_Fit_y_Quad_Current.png | 300px]]
 +
  
  
Line 83: Line 95:
 
===20mA===
 
===20mA===
 
[[File:HRRL_05-15-3011-Scan_Q1_20mA_Par_Fit_x.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_20mA_Par_Fit_x.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_20mA_Par_Fit_x_Quad_Current.png | 300px]]
 +
  
 
x-projection:
 
x-projection:
Line 93: Line 107:
  
 
[[File:HRRL_05-15-3011-Scan_Q1_20mA_Par_Fit_y.png | 300px]]
 
[[File:HRRL_05-15-3011-Scan_Q1_20mA_Par_Fit_y.png | 300px]]
 +
[[File:HRRL_05-15-3011-Scan_Q1_20mA_Par_Fit_y_Quad_Current.png | 300px]]
 +
  
 
y-projection:
 
y-projection:

Revision as of 04:04, 16 March 2011

Quad scan

1.) deliver 165 mA peak current to FC with all Quads off Ouput corrector off (H2=0,V2=0) 2.) Use Q1-Q3 to make smallest spot on the OTR

3.) Use Output corrector to center beam spot onto OTR. Record transmission.

Quad scan using Q4

Do quick quad scan with analog camera


Install digital and shielding

Quad current STOR image
200 px

Scan Results

Scan_Quad1

163mA

HRRL 05-15-3011-Scan Q1 163mA Par Fit x.png HRRL 05-15-3011-Scan Q1 163mA Par Fit x Quad Current.png


x-projection:

emit=0.236 +- 0.001 mm*mrad, emit_norm=4.622 +- 0.018 mm*mrad

beta=0.574 +- 0.001, alpha=0.895 +-0.002

HRRL 05-15-3011-Scan Q1 163mA Par Fit y.png HRRL 05-15-3011-Scan Q1 163mA Par Fit y Quad Current.png


y-projection:

emit=0.299 +- 0.003 mm*mrad, emit_norm=5.846 +- 0.054 mm*mrad

beta=0.315 +- 0.001, alpha=-0.742 +-0.004

80mA

HRRL 05-15-3011-Scan Q1 80mA Par Fit x.png HRRL 05-15-3011-Scan Q1 80mA Par Fit x Quad Current.png


x-projection:

emit=0.110 +- 0.001 mm*mrad, emit_norm=2.151 +- 0.014 mm*mrad

beta=0.378 +- 0.001, alpha=0.957 +-0.003


HRRL 05-15-3011-Scan Q1 80mA Par Fit y.png HRRL 05-15-3011-Scan Q1 80mA Par Fit y Quad Current.png


y-projection:

emit=0.281 +- 0.002 mm*mrad, emit_norm=5.491 +- 0.030 mm*mrad

beta=0.546 +- 0.001, alpha=-0.873 +-0.003


40mA

HRRL 05-15-3011-Scan Q1 40mA Par Fit x.png HRRL 05-15-3011-Scan Q1 40mA Par Fit x Quad Current.png


x-projection:

emit=0.267 +- 0.002 mm*mrad, emit_norm=5.224 +- 0.033 mm*mrad

beta=0.449 +- 0.001, alpha=1.142 +-0.004



HRRL 05-15-3011-Scan Q1 40mA Par Fit y.png HRRL 05-15-3011-Scan Q1 40mA Par Fit y Quad Current.png


y-projection:

emit=0.731 +- 0.004 mm*mrad, emit_norm=14.303 +- 0.076 mm*mrad

beta=0.382 +- 0.001, alpha=-0.613 +-0.002


20mA

HRRL 05-15-3011-Scan Q1 20mA Par Fit x.png HRRL 05-15-3011-Scan Q1 20mA Par Fit x Quad Current.png


x-projection:

emit=0.245 +- 0.002 mm*mrad, emit_norm=4.804 +- 0.031 mm*mrad

beta=0.463 +- 0.001, alpha=1.139 +-0.004


HRRL 05-15-3011-Scan Q1 20mA Par Fit y.png HRRL 05-15-3011-Scan Q1 20mA Par Fit y Quad Current.png


y-projection:

emit=0.699 +- 0.003 mm*mrad, emit_norm=13.673 +- 0.063 mm*mrad

beta=0.459 +- 0.001, alpha=-0.601 +-0.002


Peak Current (mA) Horizontal Emittance (mm*mrad) Vertical Emittance (mm*mrad)
163 4.6 5.8
80 2.2 5.5
40 5.2 14.3
20 4.8 13.7

Summary

Peak Beam current [math] \epsilon_{nx}[/math] [math]\epsilon_{ny}[/math]
(mA) (mm-mrad) mm-mrad
0.102 29 72
20 4.8 13.6
40 5.2 14.3
80 2.1 5.4
163 4.6 5.8
If there is a space charge effect, shouldn't emittance increase with beam current?


HRRL_Emittance_Measurements_March14-18-2011