HRRL 03-14-2011

From New IAC Wiki
Jump to navigation Jump to search

Beam alignment

The goal will be to determine the HRRL steerer and solenoid settings to transport 10 MeV electrons down the zero-line. The desired current is 80 mA peak and 50 nsec wide pulses, ~ 10 Hz repetition rate (or a rate to see OTR images).


Find Best Steering Set

1) The most upstream solenoid is used to adjust the gun emmittance and the downstream solenoid will adjust the beam size. Turn off both solenoids

2) Turn off all the quads.

3) Maximize the transmission along the zero beam line using the front and rear steering coils

4) Turn on the beam downstream solenoid and to adjust the beam spot size. If the beam spot moves on the OTR target, then the beam is not coming out of the HRRL.beam center moves on the screen?

5) Adjust the HRRL steering coils until the beam spot does not move when the downstream solenoid current changes.

6) Repeat step 3 and 4, until beam center does not change by change solenoid strength.

This is the best steering set. Record corresponding current settings.

Quad centering

1) Turn on just one quad at a time. Change quad strength, see if there is steering by the quad.

2) If there is steering by the quad, move the quad. If the steering is vertical (horizontally) move the quad vertically (horizontally). Do it Until beam can not be steered by the quad.

3) Repeat 2 for all the quads.


Beam Line Alignment

1) We moved first dipole to the beam right. Front of moved 6 mm, back moved 12mm.

Out put vertical steering at 0 Amp, beam went of the screen. When current was increased beam spot goes down to the viewer (OTR).

2) We moved a lot back and forth since step 1), we lost track.

Camera Orientation.

HRRL Test Mar 13 2011 Beam Orientation.png


Moving OTR target & FC for Max trans

We turn off the solenoids.

We use the steerers that are closest to the Gun (Input Horizontal/Vertical)



FC Current H1 (Input Horizontal) V1 (Input Vertical) FC + OTR move
mA A A
35 + 0.0 +0.3 5 mm beam right
60 +0.2 -0.1 4 mm beam right
7 +0.3 -0 8 mm beam right
34 +0.3 -0 4 mm beam left
65 +.3 0 Moved From OTR beam right 2 mm and rear FC beam left 6 mm (rotation)
66.5 .2 0 Chad optimized H1 and H2 for maximum current
48 .2 0 rotated OTR some more, 4 mm , FC was 8 mm beam left of spot it is now 5 mm from spot, should move FC beam left 3 mm, OTR target looks centered now.
51.6 .2 .2 Chad optimized H1 and H2 for maximum current