# The circuit board voltage fluctuations.
 
# The circuit board voltage fluctuations.
#The following reference has almost the same conditions as those of our detector when the type of particles detected is considered.
+
#The following reference describes almost the same conditions as those of our detector when their detector is in operation to detect simultaneously photons with alpha particles.
  
 
Nuclear Instruments and Methods in Physics Research A 471 (2001) 151–155, (www.researchgate.net/...a.../0fcfd50c20764a92e1000000)
 
Nuclear Instruments and Methods in Physics Research A 471 (2001) 151–155, (www.researchgate.net/...a.../0fcfd50c20764a92e1000000)
  
The author commented by the end "The studies show that GEMs can operate at extremely high rates (>106 Hz/mm2) with no sign
+
The author commented in the conclusion "The studies show that GEMs can operate at extremely high rates (>10^6 Hz/mm^2) with no sign
of degradation and stability loss due to radiation damage. However, it was discovered that the maximum achievable gain for all planar gaseous
+
of degradation and '''stability loss''' due to radiation damage. However,  
detectors drops with the beam intensity"
+
'''it was discovered that the maximum achievable gain for all planar gaseous detectors drops with the beam intensity''' "
  
 
"In real clinical operation the detector can operate safely with a gain of 10^2 in the GEM closest to the collector".
 
"In real clinical operation the detector can operate safely with a gain of 10^2 in the GEM closest to the collector".
 +
 +
  Our detector has a rate of 10 Hz, considering  the detector age, will this rate cause an instability?
  
 
=9/18/14=
 
=9/18/14=

Revision as of 21:24, 20 September 2014

09/20/14

The figure below shows the change in the signal as the GEM capacitor charges, at a specific fixed voltage it reaches saturation (equilibrium),

GEM signal time equilibS.png

If the capacitor does not reach equilibrium, the signal of the detector is expected to change with time.


 What may forbid the GEM capacitor to reach the equilibrium?
  1. The circuit board voltage fluctuations.
  2. The following reference describes almost the same conditions as those of our detector when their detector is in operation to detect simultaneously photons with alpha particles.

Nuclear Instruments and Methods in Physics Research A 471 (2001) 151–155, (www.researchgate.net/...a.../0fcfd50c20764a92e1000000)

The author commented in the conclusion "The studies show that GEMs can operate at extremely high rates (>10^6 Hz/mm^2) with no sign of degradation and stability loss due to radiation damage. However, it was discovered that the maximum achievable gain for all planar gaseous detectors drops with the beam intensity "

"In real clinical operation the detector can operate safely with a gain of 10^2 in the GEM closest to the collector".

 Our detector has a rate of 10 Hz, considering  the detector age, will this rate cause an instability?

9/18/14

Determine best Cathode HV that produces the largest separation of the source ON/OFF signal.

The detector results are not reproducible, as the voltage is at 3.4 kV, the QDC spectrum is different as the source on; so QDC can not distinguish if the source is on or when it is off the detector.

Something is wrong!!!!

We never have a reproducibility problem before using the QDC until I start using V1495, Can we borrow the older module just to test the reproducibility is still a problem.

It is very unlikely that it is the v1495.  The V1495 only tells the DAQ to read out a module.  
You can test the DAQ by injecting a pulse with a known charge and look for it in the QDC spectrum.
It is VERY important to have scope pictures showing the difference between source ON/OFF.
Then you use scalers to check that your trigger pulse is able to see a difference between source ON/OFF
Then you do the DAQ measurements.  
If you don't follow the above proceedure then you will be building a pyramid on quicksand.

The same case when the cathode voltage increased to 3.6 kV.


Then perform a set of measurements (shutter open/closed and source ON/OFF) to establish reproduceability. Make sure you record the scaler count rates.

9/17/14

Measure the charge for several values of the Cathode HV keeping the GEM preamplifier voltage and gas flow rate constant.

CATH 3.2 KV

QDC source on off 7728 7729.png

CATH 3.1 KV

QDC source on off 7736 7737.png

All the runs have the same duration 20 min.

CATH 3.4 KV

Try to take scope picture to show difference between source on and off signal that are being measured by the QDC.

9/16/14

QDC source on off 7724 7726.png

Condition of above results

Shutter is Open

Red is Cf-252 source ON Run 7724

Green is Cf-252 source OFF run 7726

HV_GEM= -2930 Volts HV_Cathode=-3400 Volts

Gas Flow rate = 0.1 ft^3/hr

Goal
Can the Cf-252 source ON signal be changed?

Change the Cathode voltage to try and turn off the signal when the source is on.

Result

Yes, when the cathode voltage is decreased to -3100V, QDC histogram does not show any difference in the collected charge as the shutter is open with the source on it, and when the shutter is open without the source.


The figure below shows the change in the QDC spectrum when the cathode voltage is -3.2 kV. QDC source on off 7728 7729.png


Neutron_TGEM_Detector_Abdel