Difference between revisions of "FC calibration 25 MeV 3/4/11"

From New IAC Wiki
Jump to navigation Jump to search
 
(2 intermediate revisions by the same user not shown)
Line 4: Line 4:
 
Below is the FC calibration by using view screen observation for 44 MeV setup (runs 1848-1867)
 
Below is the FC calibration by using view screen observation for 44 MeV setup (runs 1848-1867)
  
[[File:FC Calibration 3.4.11.png | 600 px]]
+
[[File:FC Calibration 3.4.11.png | 800 px]]
 +
 
 +
 
 +
Here are:
 +
 
 +
#red line is the fitting line for beam up
 +
#green line is the fitting line for beam down
 +
#black line is the fitting line for beam up and down
 +
 
 +
We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is
 +
 
 +
<math>x(cm)= 0.10 + 0.04\cdot I(Ampers)</math>
 +
 
 +
 
 +
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back]

Latest revision as of 15:38, 2 June 2011

Go Back


Below is the FC calibration by using view screen observation for 44 MeV setup (runs 1848-1867)

FC Calibration 3.4.11.png


Here are:

  1. red line is the fitting line for beam up
  2. green line is the fitting line for beam down
  3. black line is the fitting line for beam up and down

We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is

[math]x(cm)= 0.10 + 0.04\cdot I(Ampers)[/math]


Go Back