=FC analysis using ADC channel current distribution=
 
=FC analysis using ADC channel current distribution=
 
For each ADC channel:
 
For each ADC channel:
  <math> ADCSum^{channel}=\sum_{i=1}^{all pulses}{ADC_{pulse}^{channel}};</math>
+
  <math> ADCSum^{channel}=\sum_{i=1}^{#pulses}{ADC_{pulse}^{channel}};</math>
 +
<math> ADCErr^{channel}=\sqrt{\sum_{i=1}^{#pulses}{ADC_{pulse}^{channel}}};</math>
  
 
For distribution over all beam pulses:
 
For distribution over all beam pulses:

Revision as of 03:36, 5 April 2010

Go Back

FC analysis using ADC channel current distribution

For each ADC channel:

[math] ADCSum^{channel}=\sum_{i=1}^{#pulses}{ADC_{pulse}^{channel}};[/math]
[math] ADCErr^{channel}=\sqrt{\sum_{i=1}^{#pulses}{ADC_{pulse}^{channel}}};[/math]

For distribution over all beam pulses:

[math] ADC_{ave}=\frac{\sum_{i=1}^{pulses}{ADC_{avg}^{pulse}}}{pulses};[/math]
[math] ADC_{sigma}={ \sqrt{\frac{1}{pulses}\sum_{i=1}^{pulses}{\left(ADC_{avg}^{pulse} - ADC_{avg}\right)^{2}}}};[/math]





FC analysis using pulse by pulse ADC channel mean value distribution

For each beam pulse:

[math] ADC_{avg}^{pulse}=\frac{\sum_{i=1}^{16}{ADC_{i}*i}}{\sum_{i=1}^{16}{ADC_{i}}};[/math]

For distribution over all beam pulses:

[math] ADC_{ave}=\frac{\sum_{i=1}^{pulses}{ADC_{avg}^{pulse}}}{pulses};[/math]
[math] ADC_{sigma}={ \sqrt{\frac{1}{pulses}\sum_{i=1}^{pulses}{\left(ADC_{avg}^{pulse} - ADC_{avg}\right)^{2}}}};[/math]

Here is:
1. ADC# = bridge#
2. Pulse# = ReadOut# = Entry# = Event#

FC data 23.png

FC plot 2 4.png



Some examples of ADC mean value distribution. Here are:
1. x axis: ADC mean value for one pulse
2. y axis: number of pulse w/ that ADC mean value
1477 1.png1473 1.png
1461 1.png1465 1.png

Below is the plot of the charge in Faraday cup (pC) as a function of magnet current (vertical axis, A) (basically magnetic field) and ADC (horizontal axis).

Far.jpg