&deg;Calculated by TSO using <math>\dot x = \frac {\Gamma A }{ D^2} </math> where <math> \Gamma = 3.3 \frac {(cm^2)(R)}{(mCi)(hr)} </math> , <math>A = 9.3 Ci </math> , <math>D=(Distance to faceplate + 11.2cm </math>
+
&deg;Calculated by TSO using <math>\dot x = \frac {\Gamma A }{ D^2} </math> where <math> \Gamma = 3.3 \frac {(cm^2)(R)}{(mCi)(hr)} </math>, <math>A = 9.3 Ci </math>, <math>D=(\text{Distance to faceplate} + 11.2cm </math>
  
 
Total dose calculated by <math>\int\limits_{t_0}^{t_f}\dot x\ dt </math>
 
Total dose calculated by <math>\int\limits_{t_0}^{t_f}\dot x\ dt </math>

Revision as of 18:16, 12 October 2017

Source Calibration and Dose Rate Data

Date Initial Source Strength (Ci) Current Source Strength (Ci) Distance to Source (cm) Exposure Rate (Roentgen/hr)°
6/27/17 20 9.3 30.5 17.691
9/11/17 20 9.3 30.5 17.606

°Calculated by TSO using [math]\dot x = \frac {\Gamma A }{ D^2} [/math] where [math] \Gamma = 3.3 \frac {(cm^2)(R)}{(mCi)(hr)} [/math], [math]A = 9.3 Ci [/math], [math]D=(\text{Distance to faceplate} + 11.2cm [/math]

Total dose calculated by [math]\int\limits_{t_0}^{t_f}\dot x\ dt [/math]

137Cs Shot Log

Dot OSLs

Date Run Number Run Time (s) Distance to Source Number of OSLs in Stack
9/8/17 1 5660 30cm 11
9/8/17 1 5660 30cm 11
9/26/17 2 4500 30cm 11
9/26/17 2 4500 30cm 11

Nanodot OSL Quality Control

Date Run Number Run Time (s) Distance to Source Number of OSLs Total Exposed Dose Measured Dose Adjusted Dose
10/12/17 1 284.04 30.5cm 3 - - -



Reproducibility with 137Cs