Difference between revisions of "Conversion TDC to Energy"

From New IAC Wiki
Jump to navigation Jump to search
Line 102: Line 102:
  
 
We calibrated ADC [[http://www.iac.isu.edu/mediawiki/index.php/TDC_Calibration]] and using those data we can tell energy of neutron by its relative channel number difference from gamma peak.
 
We calibrated ADC [[http://www.iac.isu.edu/mediawiki/index.php/TDC_Calibration]] and using those data we can tell energy of neutron by its relative channel number difference from gamma peak.
 +
 +
 +
There a two scale for ADC. One is 2000 ns, the other one is 4000ns.
 +
 +
For 2000 ns scale:
  
 
[[Image:method 2 polarized 2000 channels.pdf]]
 
[[Image:method 2 polarized 2000 channels.pdf]]
 +
 +
 +
For 4000 ns scale:
  
 
[[Image:method 2 polarized 4000 channels.pdf]]
 
[[Image:method 2 polarized 4000 channels.pdf]]

Revision as of 06:14, 18 November 2008

Method 1:

Calculation

When electron beam hit the radiator, TDC start to count. It will take gamma 14 ns to reach the target. Then after some time [math]t_{n1}[/math], neutron arrive to the detectors.

Let's call the the total time from electron beam hit the radiator to neutron to be detected is [math]t_n[/math]. So,

[math]t_n = t_{n1} + 14 = \frac{d}{v} + 14 ns[/math]

where d is the distance between detector and target, v is speed of neutron. So,

[math]v=\frac{d}{(t-14)*10^{-9}} m/s [/math]

where should be in the unit of nano second.

Setup.jpg



[math]\beta_n=\frac{v}{c}[/math]

[math]\gamma_n=\sqrt{\frac{1}{1-\beta^2}}[/math]

[math]E_{tot}=M_n\gamma_nc^2[/math]

[math]E_k=E_{tot}-M_n c^2[/math]

Data

For data go to link:

http://inca.iac.isu.edu/~setiniyaz/photofis/Method1/

or click on:

File:Method 1 polarized.pdf

File:Method 1 unpolarized top.pdf

File:Method 1 unpolarized side.pdf

Method 2: Using time difference in two peaks

Calculation

If we assume gamma flash is coming from target, then by time difference in gamma peak and neutron peak, we can tell the energies in neutrons.

[math]t_n[/math]: Neutron time of flight

[math]t_{\gamma}[/math]: Gamma time of flight

d: Distance between detector and target.

d for polarized case: [math]d_{pol}[/math] = 91.25 inches = 231.775 cm.

d for unpolarized top detector: [math]d_{unpol top}[/math]=96.25 inches = 244.745 cm.

d for unpolarized side detector: [math]d_{unpol side}[/math]=91.39 inches = 232.131 cm.


[math]t_n-t_{\gamma}=\frac{d}{v}-\frac{d}{c}=d(\frac{1}{v}-\frac{1}{c}[/math])

=> [math]v=\frac{1}{\frac{t_n-t_{\gamma}}{d}-\frac{1}{c}}[/math]


[math]\beta_n=\frac{v}{c}[/math]

[math]\gamma_n=\sqrt{\frac{1}{1-\beta^2}}[/math]

[math]E_{tot}=M_n\gamma_nc^2[/math]

[math]E_k=E_{tot}-M_n c^2[/math]





Data

For data go to Link below:

http://inca.iac.isu.edu/~setiniyaz/photofis/TDCtoMeV/

or click on:

File:Method 2 polarized.pdf

File:Method 2 unpolarized top.pdf

File:Method 2 unpolarized side.pdf

Energy vs Channel

We calibrated ADC [[1]] and using those data we can tell energy of neutron by its relative channel number difference from gamma peak.


There a two scale for ADC. One is 2000 ns, the other one is 4000ns.

For 2000 ns scale:

File:Method 2 polarized 2000 channels.pdf


For 4000 ns scale:

File:Method 2 polarized 4000 channels.pdf


go back