Difference between revisions of "CaGaS Phase II"

From New IAC Wiki
Jump to navigation Jump to search
(16 intermediate revisions by the same user not shown)
Line 1: Line 1:
<big>'''CaGaS Phase II is a repeat of capture gamma energy spectroscopy experiments performed during the summer of 2021 in the ISU clean room. The purpose of revisiting the capture gamma experiment is to use a new, higher activity <sup>252</sup>Cf source (U2-622) and to investigate different thicknesses of Gadolinium foils and the effect on the high energy photon flux produced. This work is being performed in support of the main conversion process for the In-Situ Positron Annihilation Spectroscopy experiment being designed and performed by INL staff and external collaborators.'''</big>
+
<big>'''CaGaS Phase II (Capture Gamma Spectroscopy) is a repeat of capture gamma energy spectroscopy experiments performed during the summer of 2021 in the ISU clean room. The purpose of revisiting the capture gamma experiment is to use a new, higher activity <sup>252</sup>Cf source (U2-622) and to investigate different thicknesses of Gadolinium foils and the effect on the high energy photon flux produced. This work is being performed in support of the main conversion process for the In-Situ Positron Annihilation Spectroscopy experiment being designed and performed by INL staff and external collaborators.'''</big>
  
='''Impromptu To Do List'''=
+
='''To Do'''=
  
*Investigate the difference with/out PUR (pile up rejection) enabled on spec amp
+
*Measure up as close to Gd as possible and then ~12" away to calculate the adjustment factors necessary for coincidences
**Look for differences with high count rate source
 
  
*Build shielded tunnel for Gd optimal thickness measurements
+
='''Weekly Reports'''=
**Both Gd powder and foils
 
**Design and print holders for foils and powder
 
**Measure up as close to Gd as possible and then ~12" away to calculate the adjustment factors necessary for coincidences
 
  
*Calculate the deadtime for each efficiency measurement using the method outlined on pgs. 83-84 of Practical Gamma Ray Spectrometry by Gordon Gilmore, poorly summarized below.
+
[[CH Weekly Reports]]
**DT=RT-LT or we can rearrange using graduate level mathematics to LT=RT-DT -> ''not necessarily correct apparently''
 
**Note that the gate is "open" when the ADC is "NOT" busy (read as no pulse is currently being analyzed)
 
**Real time = total measurement time
 
**Dead time = amount of time gate is "closed" (effectively total counts x gate width(?))
 
**Dead time as a percent is 100x(RT-LT)/RT
 
**Calculate real count rate by total counts/live time
 
**Could count number of gates on scalar to get relatively accurate number of total gates triggered, however RCGUI events should give the correct number (subtract 3 for prestart, start, and end events)
 
**'''Need accurate gate width measurement for this process'''
 
**<small><math>\text{T}_D</math></small>=2.8μs
 
 
 
[[CH_785NADC]]
 
  
 
='''I) CaGaS Phase II Associated Equipment and Experimental Setup'''=
 
='''I) CaGaS Phase II Associated Equipment and Experimental Setup'''=
Line 39: Line 24:
  
 
[[CH_HPGe_Electronics_Chain]]
 
[[CH_HPGe_Electronics_Chain]]
 +
 +
[[CH_785NADC]]
  
 
=='''Gadolinium'''==
 
=='''Gadolinium'''==
  
 
[[CH Gd Holders]]
 
[[CH Gd Holders]]
 
=='''Shielded Tunnel'''==
 
 
^ Come up with a ''cooler'' name
 
  
 
='''II) Neutron Attenuation Measurements'''=
 
='''II) Neutron Attenuation Measurements'''=
Line 62: Line 45:
 
[[CH He3 Attenuation Measurements: 3 Different Cf252 Sources]]
 
[[CH He3 Attenuation Measurements: 3 Different Cf252 Sources]]
  
='''III) CaGaS Phase I Expansion'''=
+
='''IV) HPGe'''=
 
 
[[CaGaS Phase I Gadolinium]]
 
 
 
[[CaGaS Phase I Cadmium]]
 
 
 
='''IV) HPGe Measurements'''=
 
  
 
[[PAS HPGe Detector]]
 
[[PAS HPGe Detector]]
  
 
[[CH HPGe Efficiency]]
 
[[CH HPGe Efficiency]]
 +
 +
[[CH DAQ2 Energy Calibration]]
  
 
='''V) CaGaS Phase II'''=
 
='''V) CaGaS Phase II'''=
Line 83: Line 62:
  
 
='''Useful Resources'''=
 
='''Useful Resources'''=
 +
 +
[[CH_Code_Repository]]
  
 
[[CH ROOT Nonuniform Binning]]
 
[[CH ROOT Nonuniform Binning]]

Revision as of 18:05, 21 November 2022

CaGaS Phase II (Capture Gamma Spectroscopy) is a repeat of capture gamma energy spectroscopy experiments performed during the summer of 2021 in the ISU clean room. The purpose of revisiting the capture gamma experiment is to use a new, higher activity 252Cf source (U2-622) and to investigate different thicknesses of Gadolinium foils and the effect on the high energy photon flux produced. This work is being performed in support of the main conversion process for the In-Situ Positron Annihilation Spectroscopy experiment being designed and performed by INL staff and external collaborators.

To Do

  • Measure up as close to Gd as possible and then ~12" away to calculate the adjustment factors necessary for coincidences

Weekly Reports

CH Weekly Reports

I) CaGaS Phase II Associated Equipment and Experimental Setup

Polyethylene

CH_Poly_Density

Radioactive Sources

CH Cf252 Sources

CH Calibration Sources

Electronics Chain

CH_HPGe_Electronics_Chain

CH_785NADC

Gadolinium

CH Gd Holders

II) Neutron Attenuation Measurements

Discriminator Dual Pulsing Investigation

CH Discriminator Dual Pulsing

Initial Measurements

CH He3 Attenuation Measurements

Revisited Measurements

CH He3 Attenuation Measurements: 3 Different Cf252 Sources

IV) HPGe

PAS HPGe Detector

CH HPGe Efficiency

CH DAQ2 Energy Calibration

V) CaGaS Phase II

CH Phase II Run Plan

Previous Work

CaGaS Phase I

Useful Resources

CH_Code_Repository

CH ROOT Nonuniform Binning

CH_PAS_Master_Logbook

CH_Isotope_Table

CH_Reading_CODA_Data

CH NIM Bin Repair

CH Meeting Notes

Previous Page

PAS Experiment