Difference between revisions of "CHIPS IAC Run 5-29-08"

From New IAC Wiki
Jump to navigation Jump to search
Line 42: Line 42:
 
|Device || setting
 
|Device || setting
 
|-
 
|-
| RS1 || 0+
+
| RS1 || -14.96
 
|-
 
|-
| RS2 || 0-
+
| RS2 || +0
 
|-
 
|-
|FS1 || 0+
+
|FS1 || 0
 
|-
 
|-
|FS2 || 0-
+
|FS2 || 8.58
 
|-
 
|-
|0Q1 || -0.20
+
|0Q1 || -14.75
 
|-
 
|-
|0Q2 || +2.86
+
|0Q2 || +2.26
 
|-
 
|-
|45Q1 || -0.004
+
|45Q1 || -0.62
 
|-
 
|-
|45Q2 || +2.24
+
|45Q2 || +1.88
 
|-
 
|-
|L90Q1 || -1.33
+
|L90Q1 || -2.62
 
|-
 
|-
|L90Q2 || +2.42
+
|L90Q2 || +2.83
 
|-
 
|-
|Bend1 || 3.5
+
|Bend1 || -3.42
 
|-
 
|-
|Bend2 || 0.86
+
|Bend2 || -5.3 (3 MeV)
 
|-
 
|-
|Gun HV|| 13 kV
+
|Gun HV|| 3 kV
 
|-
 
|-
|Grid|| 2.31
+
|Grid|| 1.64
 
|-
 
|-
|802 || 16 kV
+
|802 || 15.7 kV
 
|-
 
|-
|SOL1 || 0.39
+
|SOL1 || 0
 
|-
 
|-
|SOL2 || 0.40
+
|SOL2 || 3.58
 
|}
 
|}
  

Revision as of 15:48, 29 May 2008

Calibration

Run # MPA file name Description
40 NaI040.mpa Na-22 source in front of HpGe and Co-60 on top of NaI detector
41 NaI019.mpa Co-60 source in front of HpGe and Na-22 on top of NaI detector

Last Dipole Sweep

Tune 10 Mev onto Tungsten and 4 MeV into Cell

We put in two thin pieces (thickness ~1/4" each) making a ~1/2" of lead angled at ~30 degrees wrt vertical between the NaI detector and the collimator to cut down on low-energy (< 200 keV) photons.


Run # MPA file name W Ta Description
45 NaI045.mpa IN IN Dipole at 2 MeV (0.78 on Pot), 60 Hz rep rate
46 NaI046.mpa IN IN Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 116 [math]\pm[/math] 15 counts at 500 keV, Live=929 seconds
47 NaI047.mpa IN Out Dipole at 2 MeV (0.78 on Pot), 300 Hz rep rate, 53 [math]\pm[/math] 9 counts at 500 keV, Live=607 seconds, (Tant IN/Out ratio =116/53 [math]\times[/math] 607/929 = 1.4)
48 NaI048.mpa IN Out Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 90 [math]\pm[/math] 11 counts at 500 keV, Live=600 seconds, ignore NaI (cable not plugged into scope)
49 NaI049.mpa IN In Dipole at 3 MeV (1.13 on Pot), 300 Hz rep rate, 113[math]\pm[/math] 12 counts at 500 keV, Live=634 seconds,plugged NaI cable back into scope in middle of run. ((Tant IN/Out ratio =113/90 = 1.26 )


Accelerator Gun problem (ground wire shielding was worn away and creating path for short)


Restore tune with settings below.:

Device setting
RS1 -14.96
RS2 +0
FS1 0
FS2 8.58
0Q1 -14.75
0Q2 +2.26
45Q1 -0.62
45Q2 +1.88
L90Q1 -2.62
L90Q2 +2.83
Bend1 -3.42
Bend2 -5.3 (3 MeV)
Gun HV 3 kV
Grid 1.64
802 15.7 kV
SOL1 0
SOL2 3.58
Run # MPA file name W Ta Description
56 NaI056.mpa IN In Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. 48[math]\pm[/math] 8 counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.
57 NaI057.mpa IN Out Dipole at 3 MeV (1.11 on Pot), 300 Hz rep rate, (802 set to 15.7 kV. [math]\pm[/math] counts at 500 keV, Live=600 seconds, grid = 1.64, Gun = 3 kV.