Beam Test Jul 19 2012

From New IAC Wiki
Revision as of 15:29, 19 July 2012 by Setisadi (talk | contribs) (→‎runs)
Jump to navigation Jump to search

Tune up 10 MeV on the zero line.

Insert Tungsten target and do a dipole scan to determine relative yield as a function of energy. Attempt to measure relative yield using integral of thick scintillator output for constant current and energy slit setting.

HRRL 10MeVePdist 71812.png

10 MeV Tune

Energy Switch Out (High En)
Solenoid 1 6.2 A
Solenoid 2 3.3 A
Gun Hor -0.2 A
Gun Ver 0 A
Output Hor -0.3 A
Output Ver 0 A
Rep Rate 8
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10 (Knob Setting)
RF frequency 2856.320 MHz
Modulator HV Power Supply 4.28 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) -3.7
Q2 (A) -5.5
Q3 (A) +0.6

runs

W1 Sweeping magnet D1 (A) D2 (A) Mode Jaw width (cm) q4 (A) q5 (A) q6 (A) q7 (A) q8 (A) q9 (A) q10 (A) Counts Time (s) counts/second Area of pulse (nVs) conditions
in out 4.2 4.2 e- 0.5 0 0 0 0 0 0 0 856 100.1 8.55 D1 & D2 set to 2 MeV e- for 90 deg
in out 0 4.2 0.5 0 0 0 0 0 0 0 7.13 100 7.13 no bending
in out 4.2 4.2 bg 0.5 0 0 0 0 0 0 0 136 80.1 1.7 RF on, Gun off
in out 4.2 4.2 bg 0.5 0 0 0 0 0 0 0 120 70 1.7 Clystron HV on, RF off, Gun off
in out 4.2 4.2 e- 0.5 -4.0 +1.9 0 0 0 0 0 818 99.9 8.19 D1 & D2 set to 2 MeV e- for 90 deg


W1 Sweeping magnet D1 (A) D2 (A) Mode Jaw width (cm) Sint HV q4 (A) q5 (A) q6 (A) q7 (A) q8 (A) q9 (A) q10 (A) Counts Time (s) counts/second Area of pulse (nVs) conditions
in out 4.2 4.2 2 MeV e- 1 1000 V +1.1 +3.3 -2.4 0 +0.2 0 +0.2 518 139.9 3.7 D1 & D2 set to 2 MeV e-