Difference between revisions of "Beam Test Jul 17 2012"

From New IAC Wiki
Jump to navigation Jump to search
Line 40: Line 40:
  
 
= 3 MeV tests =  
 
= 3 MeV tests =  
 +
 +
Electron beam tune is same as yesterday, tuned for 11.5 region.
  
 
Start from where I left from yesterday. Repeat the last measurement from yesterday, so I can reproduce yesterday's condition, and start from there. Yesterday, the sweeping magnet added to the end of the 3rd triplet magnets to sweep the beam.  
 
Start from where I left from yesterday. Repeat the last measurement from yesterday, so I can reproduce yesterday's condition, and start from there. Yesterday, the sweeping magnet added to the end of the 3rd triplet magnets to sweep the beam.  
Line 67: Line 69:
 
|-
 
|-
 
|}
 
|}
 +
 +
 +
= 2 MeV tests =

Revision as of 15:28, 17 July 2012

Tune

Used tune from yesterday.

Energy Switch Out (High En)
Solenoid 1 6.9 A
Solenoid 2 1.3 A
Gun Hor 0 A
Gun Ver +0.2 A
Output Hor +1.2 A
Output Ver 0 A
Rep Rate 8
Gun HV 10 (Knob Setting)
Gun Grid Voltage 6.42 (Knob Setting)
RF frequency 2856.320 MHz
Modulator HV Power Supply 4.28 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) -10
Q2 (A) -10
Q3 (A) 0

3 MeV tests

Electron beam tune is same as yesterday, tuned for 11.5 region.

Start from where I left from yesterday. Repeat the last measurement from yesterday, so I can reproduce yesterday's condition, and start from there. Yesterday, the sweeping magnet added to the end of the 3rd triplet magnets to sweep the beam.


The Gun grid voltage was set back to 6.42 (knob Setting), similar as the last run on yesterday.


W1 Sweeping magnet D1 (A) D2 (A) Mode Jaw width (cm) q4 (A) q5 (A) q6 (A) q7 (A) q8 (A) q9 (A) q10 (A) Counts Time (s) counts/second conditions
in out 0 0 photon 0.2 - 2 +2 0 0 0 -0.6 - 0.4 1163 305.7 3.80 Beam tuned to 0 deg
in out 0 -5.8 positron 0.2 - 2 +2 0 0 0 -0.6 - 0.4 1401 378.5 3.70 Beam tuned to 0 deg
in out -5.8 -5.8 positron 0.2 - 2 +2 0 0 0 -0.6 - 0.4 1362 349.6 3.90
in out 0 0 0.2 - 2 +2 0 0 0 -0.6 - 0.4 1204 315.1 3.82
in out -5.8 5.8 0.2 - 2 +2 0 0 0 -0.6 - 0.4 1292 359.8 3.59
in out -5.8 5.8 0.2 - 2 +2 0 0 0 -0.6 - 0.4 566 150.1 3.77
in out 5.8 5.8 electron 0.2 - 2 +2 0 0 0 -0.6 - 0.4 1417 220 6.44 D1 & D2 tuned for 3 Mev electron. Quads are still in positron mode setting.
in out 5.8 5.8 electron 0.2 + 2 -2 0 0 0 +0.6 + 0.4 2467 219.8 11.22 D1 & D2 tuned for 3 Mev electron.


2 MeV tests