Beam Test Jul 16 2012

From New IAC Wiki
Jump to navigation Jump to search

Camera Trig

Tune the beam for 15 MeV range, see the beam with camera. Get camera triggering.

Tune The Beam for 10 MeV

2nd Tuning (10 MeV)

Energy Switch
Solenoid 1 3.0 A
Solenoid 2 5.2 A
Gun Hor 0.1 A
Gun Ver 0.1 A
Output Hor -0.1 A
Output Ver -0.3 A
Rep Rate 10
Gun HV 10 (Knob Setting)
Gun Grid Voltage 10(Knob Setting)
RF frequency 2856.269 MHz
Modulator HV Power Supply 4.13 (Knob Setting)
RF macro Pulse Length (FWHM) 300 ns
Q1 (A) 0
Q2 (A) 0
Q3 (A) 0
Q4 (A) 0
Q5 (A) 0
Q6 (A) 0