Difference between revisions of "2n opening angle"

From New IAC Wiki
Jump to navigation Jump to search
Line 37: Line 37:
 
[[File:Total_data_simulation.png | 1000 px]]
 
[[File:Total_data_simulation.png | 1000 px]]
  
The plot on the left was normalized to the total number of neutron pairs sampled during the simulation.
+
The plot on the right was normalized to the total number of neutron pairs sampled during the simulation.
  
 
The result of division of experimental data histogram by the normalized simulation data histogram is shown below:
 
The result of division of experimental data histogram by the normalized simulation data histogram is shown below:
  
 
[[File:Total_data_geom_corrected.png | 600 px]]
 
[[File:Total_data_geom_corrected.png | 600 px]]

Revision as of 22:53, 30 December 2012

Experimental data

2n opening angle obtained after the processing of all the runs with thick uranium target is shown below:

Total data ana.png

The bin width (x-error) is 7.2 degrees, the total number of bins is 25. Statistical error (y-error) is presented for each bin.

At this stage there is no efficiency normalization involved in the calculation. The main goal is to show that we've got 258 neutrons in all the runs.

Simulation

GEANT4 was used to sample two neutrons isotropically, to track them and opening angle was observed for two cases when (1) two neutrons hit the same detector (N(same)) and (2) two neutrons hit two different detectors (N(different)). After that the plot of N(different)/(N(same)+N(different)) was made.

The total number of neutron pairs sampled was [math]25 \cdot 10^5[/math], emission of neutrons was in [math]4 \pi[/math] form isotropic point source. Geometry of the experiment was preserved.

The 2n opening angle for the case (1) is shown below:

Multi hit same.png

The 2n opening angle for the case (2) is shown below:

Multi hit different.png

It can be seen that the probability to hit two different detectors about twice larger than the probability to hit the same detector for the isotropic point source of neutrons.

The plot of N(different)/(N(same)+N(different)):

Multihit percentage.png

Hence, (A) in the experimental data we can not see neutron pairs with the opening angle less then ~5 degrees because they all are multi-hit data, (B) multi-hit data disappear at 2n opening angle above 40 degrees.

Correction of experimental data for the geometry

As it was shown above we could not detect multiple hits of the same detector. In order to obtain the influence of the geometry on the data we will consider 2n opening angle for neutrons hitting two different detectors.

Comparison of the data and 2n opening angle obtained via simulation is shown below. The histograms have same number of bins (25) and same bin width (7.2).

Total data simulation.png

The plot on the right was normalized to the total number of neutron pairs sampled during the simulation.

The result of division of experimental data histogram by the normalized simulation data histogram is shown below:

Total data geom corrected.png