12 10 2012 HRRL DetectorTests

From New IAC Wiki
Jump to navigation Jump to search

RunPlan

BeamTune

Tune beam into zero line, max current, 10.5 MeV energy, 20 ns width, 300 Hz rep rate

For Reference, below is the the tune used on last day of July 2012 Positron run

https://wiki.iac.isu.edu/index.php/Beam_Test_Jul_27_2012#Tune

Measure Emittance

Ilyusha Background measurements

Previous Background tests during 2n correlation run

https://wiki.iac.isu.edu/index.php/2n_BKG_data

HV=1000 CFD = -12 mV


Previous run during neutron correlation experiment found 1 gamma/15 electron beam pulses

Tune beam into zero line, max current, 10.5 MeV energy, 20 ns width, 300 Hz rep rate

1.) Take a run with no shielding around Ilyusha

2.) Move Pb bricks around the scintillator to determine direction of background

3.) add shielding to accelerator


Rate (gamma/pulse) Beam COnfig (E,pulse width,peak current) Configuration
213/3746 = 1 /17 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 12 mV threshold on CFD, 255 ns CFD output pulse width (this width was sued in the 2n correlation exp)
213/2343 = 1/11 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 12 mV threshold on CFD, 4 ns CFD output pulse width
220/2374 = 1/11 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 12 mV threshold on CFD, 100 ns CFD output pulse width
53202/616 = nonsense 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 0 mV threshold on CFD, 4 ns CFD output pulse width
794/862 = 1/1 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 2 mV threshold on CFD, 4 ns CFD output pulse width
574/1213 = 1/2 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 4 mV threshold on CFD, 4 ns CFD output pulse width
247/906 = 1/4 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 6 mV threshold on CFD, 4 ns CFD output pulse width
662/3914 = 1/6 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 8 mV threshold on CFD, 4 ns CFD output pulse width
201/1328 = 1/6.6 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 10 mV threshold on CFD, 4 ns CFD output pulse width
220/1580 = 1/7.2 10.5 MeV : 100 ns FWHM, 5.4 mA UNshielded illyusha scintilltor, 14 mV threshold on CFD, 4 ns CFD output pulse width


Electron/photon ratio

Compare magnet in and out using a scintillator at the exit window of the 90 degree line.