Difference between revisions of "11-11-2016"

From New IAC Wiki
Jump to navigation Jump to search
Line 18: Line 18:
 
|5452 ||-||MT || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., '''discriminator thresh 40 mV''', D30 @ -1450V and all other detectors at -1500 V ,  
 
|5452 ||-||MT || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., '''discriminator thresh 40 mV''', D30 @ -1450V and all other detectors at -1500 V ,  
 
|-
 
|-
|5453 ||-||TH || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , removed battleship steel (4" wide [beamleft/right] and 30 inches high [beam up/down], now its 9" wide , green poly is on the bottom to prop up the steel
+
|5453 ||-||Th || 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , removed battleship steel (4" wide [beamleft/right] and 30 inches high [beam up/down], '''now its 9" wide , green poly is on the bottom to prop up the steel'''
 
|}
 
|}

Revision as of 22:34, 11 November 2016

Horizontal accelerator side collimator 7 mm, horizontal cell side 19 mm. 3 in of Pb on D30 & D330, 2 in of Pb on upstream side of D210, wax in front of Pb on wall downstream of beam dump

Run # D90 n Rate (Counts/pulse)E-3 Target Configuration
5446 0.53 Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 50 mV, D30 @ -1450V and all other detectors at -1500 V ,
5447 0.34 Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 70 mV, D30 @ -1450V and all other detectors at -1500 V ,
5448 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 30 mV, D30 @ -1450V and all other detectors at -1500 V ,
5449 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V ,
5450 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 60 mV, D30 @ -1450V and all other detectors at -1500 V ,
5451 - MT 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 60 mV, D30 @ -1450V and all other detectors at -1500 V ,
5452 - MT 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V ,
5453 - Th 10.5 MeV , 2 ns FWHM pulse width , 1.1 A Peak , 180.4 Hz , Radiator 1" Al., discriminator thresh 40 mV, D30 @ -1450V and all other detectors at -1500 V , removed battleship steel (4" wide [beamleft/right] and 30 inches high [beam up/down], now its 9" wide , green poly is on the bottom to prop up the steel