Difference between revisions of "05/13/2011 timing test"

From New IAC Wiki
Jump to navigation Jump to search
Line 44: Line 44:
 
:▫ plot for last 20 events (measurements on May 16, 2001)  
 
:▫ plot for last 20 events (measurements on May 16, 2001)  
 
:▫ combined plot for total 30 events
 
:▫ combined plot for total 30 events
 
{| border="0" cellspacing="0" style="text-align: center; width: 1050px; height: 100px;"
 
|[[File:Timing 1 10.png | 500px]] || [[File:Timing 11 30.png | 500px]]
 
|-
 
!colspan="6" | [[File:Timing total 30.png | 1000 px]]
 
|}
 
 
  
  

Revision as of 05:38, 19 May 2011

Go Back


Set up like that:

Detector1.png


The voltages, thresholds and widths are:

PMT voltage, V threshold, mV discr. width, ns
PS1 -1000 -80 50
PS1 -1000 -80 50
n's -1500 -200 10



Let's do the timing test. The distances are between PS1+PS2 and n's PMT. The time is time difference between PS1(PS2) and n's detector signals

Tbl timing total.png


As the distance becomes 10 cm and less the coincidence rate becomes very low. I have:

▫ 10 cm: PS1+PS2+n 11 coinc/98 min, [math](0.11\pm0.03)[/math] coinc/min
▫ 5 cm: PS1+PS2+n 103 coinc/890 min, [math](0.11\pm0.01)[/math] coins/min
▫ 5 cm: PS1 118182 coinc/890 min, [math](2.213\pm0.006)[/math] coins/min
▫ 5 cm: PS2 138573 coinc/890 min, [math](2.595\pm0.007)[/math] coins/min


Below is the plot of measured time as function of distances:

▫ plot for first 10 events (measurements on May 13, 2001)
▫ plot for last 20 events (measurements on May 16, 2001)
▫ combined plot for total 30 events


Timing 1 10.png Timing 11 30.png

Timing total 30.png