Difference between revisions of "05/13/2011 timing test"

From New IAC Wiki
Jump to navigation Jump to search
Line 62: Line 62:
  
 
As the distance becomes 10 cm my coincidence rate becomes very low:
 
As the distance becomes 10 cm my coincidence rate becomes very low:
:2 coincidence for 10 min
+
:▫ 1 coincidence for 10 min
 +
:▫ 0 coincidence for 10 min

Revision as of 23:39, 13 May 2011

Set up like that:

Detector1.png


The voltages and thresholds are:

PMT voltage, V threshold, mV discr. width, ns
PS1 -1500 -80 100
PS1 -1500 -80 100
n's -1500 -200 10



Let's do the timing test. The distances are between PS1+PS2 and n's PMT. The time is time difference between PS1(PS2) and n's detector signals

N 80 cm 70 cm 60 cm 50 cm 40 cm 30 cm 20 cm 10 cm 0 cm
1 17.6 ns 16.8 ns 16.4 ns 12.8 ns 14.0 ns 12.8 ns 14.4 ns 11.2 ns
2 17.6 ns 16.8 ns 16.8 ns 19.2 ns 14.2 ns 14.4 ns 13.6 ns
3 18.4 ns 17.6 ns 18.4 ns 17.6 ns 15.2 ns 16.8 ns 13.2 ns
4 17.6 ns 17.0 ns 17.6 ns 16.8 ns 18.6 ns 14.4 ns 14.4 ns
5 17.6 ns 17.0 ns 17.6 ns 16.8 ns 16.0 ns 14.0 ns 13.6 ns
6 17.6 ns 17.2 ns 16.4 ns 16.8 ns 17.6 ns 15.2 ns 12.4 ns
7 18.0 ns 18.4 ns 17.6 ns 16.0 ns 15.2 ns 13.2 ns 12.8 ns
8 16.8 ns 20.8 ns 16.0 ns 17.2 ns 17.2 ns 14.4 ns 12.8 ns
9 9.6 ns 17.6 ns 16.4 ns 17.2 ns 18.4 ns 17.2 ns 15.2 ns
10 17.2 ns 22.4 ns 18.4 ns 17.2 ns 16.0 ns 16.4 ns 12.8 ns
avg

As the distance becomes 10 cm my coincidence rate becomes very low:

▫ 1 coincidence for 10 min
▫ 0 coincidence for 10 min