Difference between revisions of "03-27-2015"

From New IAC Wiki
Jump to navigation Jump to search
Line 4: Line 4:
  
 
[[File:secon_hit_det1_30mV_LED.png | 400 px]]
 
[[File:secon_hit_det1_30mV_LED.png | 400 px]]
 +
 +
1. LED is in updating mode (in hope to get rid of the second pulse), 30 mV threshold, 40 ns pulse width:
 +
 +
[[File:secon_hit_det1_30mV_LED_updating.png | 400 px]]

Revision as of 15:55, 27 March 2015

Investigation of the nature of the secon peak in the second hit mode.

1. LED is in non-updating mode, 30 mV threshold, 40 ns pulse width:

Secon hit det1 30mV LED.png

1. LED is in updating mode (in hope to get rid of the second pulse), 30 mV threshold, 40 ns pulse width:

Secon hit det1 30mV LED updating.png