HRRL Pos Test 27Jul2012 Data Ana 3 MeV
Jump to navigation
Jump to search
Hand calculation on electron rate
At full current on Faraday cup 1 we have 1201 nVs/ADC channel.
charge rate under 300 Reprate:
Data
3735 sub 3736
Reprate = 300 Hz
Run time = 1002 s
Pulses = 301462
Events = 9045
e- rate = 7.80042e+013 +- 2.25903e+012 (Hz)
e+ rate = 1.41748 +- 0.0376119 (Hz).
e+/e-=1.81719e-014+-4.8238e-016.
e- current:I_e- =6.26271e-006+-3.61937e-007 (A).
e+/I_e-=1.4 Hz e+ / 6.3 \muA e-
3737 sub 3736
Reprate = 300 Hz
Run time = 1094 s
Pulses = 329368
Events = 15361
e- rate = 1.36517e+014 +- 2.39286e+012 (Hz)
e+ rate = 1.60462 +- 0.0382982 (Hz).
e+/e-=1.1754e-014+-2.8058e-016.
e- current:I_e- =1.52232e-005+-3.83378e-007 (A).
e+/I_e-=1.6 Hz e+ / 15 \muA e-
[go back]