Beam Test Jul 24 2012
Jump to navigation
Jump to search
Energy Switch | Out (High En) |
Solenoid 1 | 6.7 A |
Solenoid 2 | 1.5 A |
Gun Hor | +0.3 A |
Gun Ver | -0 A |
Output Hor | -0.4 A |
Output Ver | +0 A |
Rep Rate | 11 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10 (Knob Setting) |
RF frequency | 2856.243 MHz |
Modulator HV Power Supply | 4.19 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | -2 |
Q2 (A) | +0.8 |
Q3 (A) | +2 |
Q4 (A) | -2 |
Q5 (A) | +0.8 |
Q6 (A) | +2 |
Current at FC0 | 32 mA |
Switching T2
Originally, for T2 we used a thick target from Alfa Aesar. Dimension of the target is 25x50mm, with thickness of 2.0 mm (0.08 inch), 99.95% (metals basis).
We realized most photons can not travel through the target and go into the NaI detectors.
So, we switched T2 to the thinner target.
Calibration runs with sources
run# Source HV-DL HV-DR Pulser-period start-time end-time 3553 Na-22 1082V 1223V 20 micro-sec 19:01:34 19:58:29 3554 Na-22 1082V 1223V 5 micro-sec 20:00:50 20:11:32 3557 Na-22 1082V 1223V 10 micro-sec 3558 Na-22 1082V 1223V 10 micro-sec 3559 Na-22 1150V 1150V 10 micro-sec
run# Source HV-DL HV-DR start-time end-time 3659 Na-22 1150V 1150V 20:56:28 21:17:04 3660 Na-22 1200V 1200V 21:19:12 23:54:11 3661 Na-22 1100V 1100V 23:55:40
Fit for run 3659 Detector Left
FCN=103.893 FROM MIGRAD STATUS=CONVERGED 80 CALLS 81 TOTAL EDM=2.79556e-08 STRATEGY= 1 ERROR MATRIX ACCURATE EXT PARAMETER STEP FIRST NO. NAME VALUE ERROR SIZE DERIVATIVE 1 Constant 1.00983e+01 5.71803e-01 2.14796e-03 -4.37889e-04 2 Mean 9.59542e+02 2.82634e+00 1.41234e-02 -1.14806e-05 3 Sigma 6.19726e+01 2.65427e+00 5.40892e-05 -1.71544e-03