HRRL Positrons Jul 2012 Runs Setup
ADC inputs
Detector Left -> CH6
Detector Right -> CH5
Beam left Scintillator (between Q9 and Q10)-> CH9
Scintillator 1 (right next to the beam exit at the the 90 deg) -> CH2.
Battery -> CH13.
Note: There were some changes going on during the experiment. The above setup was according to the sent up on 27th of Jul. All the changes were recorded.
TDC input
According to the setup on 27th:
CH0->start from the gun.
CH1->95 ns delay of the start from gun.
CH5->NaI Left.
CH7->NaI Right.
13->Gate for signal (generated whenever there is a electron gun pulse, then fast cleared if there is no coincidence).
CH9-> discriminated output of NaI Left.
CH10-> discriminated output of NaI Right.
Scaler
The gun pulse connected to CH1 of the scaler . I thought I put it to CH0, may be somebody changed it.
HV power supply
We used 2CAEN Mod. N471 power supply. There are 2 of them. 2 for NaI and one for Scintilator1.
Power supply left, top channel-> NaI left
Power supply left, bottom channel-> NaI right
Power supply right, top channel-> Scintillator 1