Beam Test Jul 19 2012
Tune up 10 MeV on the zero line.
Insert Tungsten target and do a dipole scan to determine relative yield as a function of energy. Attempt to measure relative yield using integral of thick scintillator output for constant current and energy slit setting.
10 MeV Tune
Energy Switch | Out (High En) |
Solenoid 1 | 6.2 A |
Solenoid 2 | 3.3 A |
Gun Hor | -0.2 A |
Gun Ver | 0 A |
Output Hor | -0.3 A |
Output Ver | 0 A |
Rep Rate | 8 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 10 (Knob Setting) |
RF frequency | 2856.320 MHz |
Modulator HV Power Supply | 4.28 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | -3.7 |
Q2 (A) | -5.5 |
Q3 (A) | +0.6 |
Counting single pulse
Settings
Gun Grid Voltage knob setting: 2.85
Energy Switch | Out (High En) |
Solenoid 1 | 6.2 A |
Solenoid 2 | 3.3 A |
Gun Hor | -0.2 A |
Gun Ver | 0 A |
Output Hor | -0.3 A |
Output Ver | 0 A |
Rep Rate | 8 |
Gun HV | 10 (Knob Setting) |
Gun Grid Voltage | 2.85 (Knob Setting) |
RF frequency | 2856.320 MHz |
Modulator HV Power Supply | 4.28 (Knob Setting) |
RF macro Pulse Length (FWHM) | 300 ns |
Q1 (A) | -3.7 |
Q2 (A) | -5.5 |
Q3 (A) | +0.6 |
W1 | Sweeping magnet | D1 (A) | D2 (A) | Mode | Jaw width (cm) | Sintilator HV | q4 (A) | q5 (A) | q6 (A) | q7 (A) | q8 (A) | q9 (A) | q10 (A) | conditions |
in | out | 4.2 | 4.2 | 2 MeV e- | 1 | 1219 V | +1 | -0 | -0.1 | -0 | +1.3 | +0.5 | -0 | D1 & D2 set to 2 MeV e-
|
Optimization of the magnets in positron mode:
q4 q5 q6 q7 q8 q9 q10 counts / time (s) Rate (Hz) +1 -0.0 -0.1 +4.0 +1.0 +0.5 -0.0 740 / 201.4 3.67 +1 -0.0 -0.1 +4.5 +1.0 +0.5 -0.0 611 / 149.9 4.08 +1 -0.0 -0.1 +5.0 +1.0 +0.5 -0.0 360 / 100 3.6 +1 -0.0 -0.1 +4.7 +1.0 +0.5 -0.0 /