Tune up 10 MeV on the zero line.
Insert Tungsten target and do a dipole scan to determine relative yield as a function of energy. Attempt to measure relative yield using integral of thick scintillator output for constant current and energy slit setting.
10 MeV Tune
| Energy Switch |
Out (High En)
|
| Solenoid 1 |
6.2 A
|
| Solenoid 2 |
3.3 A
|
| Gun Hor |
-0.2 A
|
| Gun Ver |
0 A
|
| Output Hor |
-0.3 A
|
| Output Ver |
0 A
|
| Rep Rate |
8
|
| Gun HV |
10 (Knob Setting)
|
| Gun Grid Voltage |
10 (Knob Setting)
|
| RF frequency |
2856.320 MHz
|
| Modulator HV Power Supply |
4.28 (Knob Setting)
|
| RF macro Pulse Length (FWHM) |
300 ns
|
| Q1 (A) |
-3.7
|
| Q2 (A) |
-5.5
|
| Q3 (A) |
+0.6
|
runs
| W1 |
Sweeping magnet |
D1 (A) |
D2 (A) |
Mode |
Jaw width (cm) |
q4 (A) |
q5 (A) |
q6 (A) |
q7 (A) |
q8 (A) |
q9 (A) |
q10 (A) |
Counts |
Time (s) |
counts/second |
Area of pulse (nVs) |
conditions
|
| in |
out |
4.2 |
4.2 |
e- |
0.5 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
856 |
100.1 |
8.55 |
|
D1 & D2 set to 2 MeV e- for 90 deg
|
| in |
out |
0 |
4.2 |
|
0.5 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
7.13 |
100 |
7.13 |
|
no bending
|
| in |
out |
4.2 |
4.2 |
bg |
0.5 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
136 |
80.1 |
1.7 |
|
RF on, Gun off
|
| in |
out |
4.2 |
4.2 |
bg |
0.5 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
120 |
70 |
1.7 |
|
Clystron HV on, RF off, Gun off
|
| in |
out |
4.2 |
4.2 |
e- |
0.5 |
-4.0 |
+1.9 |
0 |
0 |
0 |
0 |
0 |
818 |
99.9 |
8.19 |
|
D1 & D2 set to 2 MeV e- for 90 deg
|
Gun current was lowered: Gun Grid Voltage know set to 6.42.
| W1 |
Sweeping magnet |
D1 (A) |
D2 (A) |
Mode |
Jaw width (cm) |
Sint HV |
q4 (A) |
q5 (A) |
q6 (A) |
q7 (A) |
q8 (A) |
q9 (A) |
q10 (A) |
Counts |
Time (s) |
counts/second |
Area of pulse (nVs) |
conditions
|
| in |
out |
4.2 |
4.2 |
2 MeV e- |
1 |
1000 V |
+1.1 |
+3.3 |
-2.4 |
0 |
+0.2 |
0 |
+0.2 |
518 |
139.9 |
3.7 |
|
D1 & D2 set to 2 MeV e-
|