Accelerator Configuration
- Accelerator Settings
beam energy |
6.8 MeV
|
Beam type: |
Electron
|
I_average: |
0.3 nA
|
I_peak: |
0.05[math] \mu[/math] A 0.006 duty factor
|
pulse width: |
10 [math]\mu[/math]s (it seems on 200 [math] \mu[/math]s is possible?)
|
Rate: |
60 Hz
|
PEPPO Spectrometer: |
151.3 A
|
Set HV to Detectors
|
Signal channel |
HV dac |
HV (V)
|
Detectors #1 |
A1 |
2.4 |
960
|
Detectors #2 |
A2 |
3.0 |
1200
|
How to turn HV On
Scope Pictures
CH1: Beam Sync
CH2: A1
CH3: A2
Target |
Pictures
|
No Target |
|
Chromox Target |
|
Annihilation Counter Runs
- Signal Definitions for Trigger logic
- SYNC:=60 Hz sync pulse 200 micro seconds long
- Det1:= Annihilation Counter #1 (HV1)
- Det2:=Annihilation Counter #2 (HV2)
Run# |
run mode |
Run length (sec) |
Beam |
Target |
Trig Logic |
VME discriminator Threshold (mV) |
HV1 (setting/V) |
HV2 (setting/V) |
Deadtime |
|
2902 |
sample |
0 |
e[math]^-[/math] |
Chromox |
(Det1 OR Det2) |
50 |
2.4/960 |
3/1200 |
93.1818% [math]\pm[/math] 10.3874% |
|
2903 |
sample |
203 |
e[math]^-[/math] |
Empty |
(Det1 OR Det2) |
50 |
2.4/960 |
3/1200 |
84.9788% [math]\pm[/math]0.106622% |
|
2904 |
sample |
452 |
e[math]^-[/math] |
Empty |
Det1 AND Det2 |
50 |
2.4/960 |
3/1200 |
12.2563% [math]\pm[/math] 2.32772% |
|
2905 |
sample |
556 |
e[math]^-[/math] |
Chromox |
Det1 AND Det2 |
50 |
2.4/960 |
3/1200 |
3.16901% [math]\pm[/math] 4.2301% |
|
2908 |
sample |
150 |
off |
out |
(Det1 or Det2) |
50 |
2.4/960 |
3/1200 |
74.0667% [math]\pm[/math] 0.157206% |
|
2909 |
sample |
1118 |
off |
out |
(Det1 AND Det2) |
50 |
2.4/960 |
3/1200 |
3.57143% [math]\pm[/math]26.9725% |
|
data analysis
Negative Energy ?
This run 2902, Int_Ch14 histogram. Why there is negative?
Pulses
run 2905
1st 100 puleses
pulse that only partially read-in:
first 10 pulses, some pulses that only partially read-in:
looks like some pulses are only partially read-in. We need to delay signal more?
One possible cut may to determine if the signal is increasing within the first 100 - 300 $Iterations. This would be like creating a leading edge discriminator in software.
T->Draw("CH14:Iteration$","Iteration$<300 & CH14<100","L",10,1)
looks like it just won't draw. I need to know the to way exclude that event does not satisfy "Iteration$<300 & CH14<100" requirement.
Why CH14 histogram is all positive, but int_14 histogram has negatives?
TF Analysis
Using the following ROOT programs
Media:03212012_T.C.txt
Media:03212012_T.h.txt
Run# |
run mode |
Run length (sec) |
Beam |
Target |
Trig Logic |
VME discriminator Threshold (mV) |
HV1 (setting/V) |
HV2 (setting/V) |
Deadtime |
|
2902 |
sample |
0 |
e[math]^-[/math] |
Chromox |
(Det1 OR Det2) |
50 |
2.4/960 |
3/1200 |
93.1818% [math]\pm[/math] 10.3874% |
|
2903 |
sample |
203 |
e[math]^-[/math] |
Empty |
(Det1 OR Det2) |
50 |
2.4/960 |
3/1200 |
84.9788% [math]\pm[/math]0.106622% |
|
2904 |
sample |
452 |
e[math]^-[/math] |
Empty |
Det1 AND Det2 |
50 |
2.4/960 |
3/1200 |
12.2563% [math]\pm[/math] 2.32772% |
|
2905 |
sample |
556 |
e[math]^-[/math] |
Chromox |
Det1 AND Det2 |
50 |
2.4/960 |
3/1200 |
3.16901% [math]\pm[/math] 4.2301% |
|
2908 |
sample |
150 |
off |
out |
(Det1 or Det2) |
50 |
2.4/960 |
3/1200 |
74.0667% [math]\pm[/math] 0.157206% |
|
2909 |
sample |
1118 |
off |
out |
(Det1 AND Det2) |
50 |
2.4/960 |
3/1200 |
3.57143% [math]\pm[/math]26.9725% |
|