PePPO 03132012
Accelerator Configuration
- Accelerator Settings
beam energy | 6.8 MeV |
Beam type: | Electron |
I_average: | 0.3 nA |
I_peak: | 0.05 | A 0.006 duty factor
pulse width: | 10 | s (it seems on 200 s is possible?)
Rate: | 60 Hz |
PEPPO Spectrometer: | 151.3 A |
Set HV to Detectors
Signal channel | HV dac | HV (V) | |
Detectors #1 | A1 | 2.4 | 960 |
Detectors #2 | A2 | 3.0 | 1200 |
Scope Pictures
CH1: Beam Sync CH2: A1 CH3: A2
Target | Pictures |
No Target | |
Chromox Target |
Annihilation Counter Runs
- Signal Definitions for Trigger logic
- SYNC:=60 Hz sync pulse 200 micro seconds long
- Det1:= Annihilation Counter #1 (HV1)
- Det2:=Annihilation Counter #2 (HV2)
Run# | run mode | Run length (sec) | Beam | Target | Trig Logic | VME discriminator Threshold (mV) | HV1 (setting/V) | HV2 (setting/V) | Deadtime | |
2902 | sample | 0 | e | Chromox | (Det1 OR Det2) | 50 | 2.4/960 | 3/1200 | 93.1818% | 10.3874%|
2903 | sample | 203 | e | Empty | (Det1 OR Det2) | 50 | 2.4/960 | 3/1200 | 84.9788% | 0.106622%|
2904 | sample | 452 | e | Empty | Det1 AND Det2 | 50 | 2.4/960 | 3/1200 | 12.2563% | 2.32772%|
2905 | sample | 556 | e | Chromox | Det1 AND Det2 | 50 | 2.4/960 | 3/1200 | 3.16901% | 4.2301%|
2908 | sample | 150 | off | out | (Det1 or Det2) | 50 | 2.4/960 | 3/1200 | 74.0667% | 0.157206%|
2909 | sample | 1118 | off | out | (Det1 AND Det2) | 50 | 2.4/960 | 3/1200 | 3.57143% | 26.9725%
Why there is negative?