September 20, 2011
summary what was been done
- current 140 mA
 - pulse width 2 us
 - rep rate 180 Hz
 - E = 25 MeV
 
| Run # | Beam | Dump magnet | Collimator | add coll | Hardener 1" Al | Radiator 25 um Al | Target | Comments | 
|---|---|---|---|---|---|---|---|---|
| 2502 | Up 90A  | 
In | Open | In | Yes | In | DU cylinder | Test radiator in/out.
 120664 pulses  | 
| 2503 | Up 90A  | 
In | Open | In | Yes | Out | DU cylinder | Test radiator in/out.
 121258 pulses  | 
| 2504 | Down 86A  | 
In | Open | In | Yes | In | DU cylinder | Test radiator in/out.
 R(bottom) = 0.00137 n/pulse   -> × 180 Hz × 60 sec/min = 14.8 n/min  | 
| 2505 | Down 86A  | 
In | Open | In | Yes | Out | DU cylinder | Test radiator in/out.
 122247 pulses  | 
Production runs
| Run # | Beam | Dump magnet | Collimator | add coll | Hardener 1" Al | Radiator 25 um Al | Target | Comments | 
|---|---|---|---|---|---|---|---|---|
| 2506 | Up 90A  | 
In | Open | In | Yes | In | DU cylinder | Long production run: 972556 pulses Operator said the beam is really jittery
 R(bottom) = 0.0013 n/pulse  -> × 180 Hz × 60 sec/min =  14.0 n/min  | 
| 2507 | Down 86A  | 
In | Open | In | Yes | In | DU cylinder | Long production run: 973769 pulses
 R(bottom) = 0.001298 n/pulse -> × 180 Hz × 60 sec/min =  14.0 n/min  | 
| 2508 | Down 86A  | 
In | Open | In | Yes | Out | DU cylinder | Long production run: pulses
 R(bottom) = 6.6E-6 n/pulse ->  × 180 Hz × 60 sec/min =   0.07 n/min  | 
| 2509 | Up 90A  | 
In | Open | In | Yes | In | DU cylinder | Long production run: pulses
 R(bottom) = 9.7E-4 n/pulse -> × 180 Hz × 60 sec/min =   10.5 n/min  |