September 14, 2011
summary what was been done
Run # | Beam | Dump magnet | Collimator | Hardener | Radiator 10 um Al | Target | Comments |
---|---|---|---|---|---|---|---|
2418 | Up 90A | In | Open | Yes | Out | DU plate | Beam check-in run. DU plate 45/45 degree orientation and gammas hit the bottom right corner of plate from upstream view.
R(beam down) = 69/53880 = 0.0013 n/pulse |
2419 | Up 90A | In | Open | Yes | Up 2 mm | DU plate | Beam check-in run. DU plate 45/45 degree orientation and gammas hit the bottom right corner of plate from upstream view.
R(beam down) = 0.00104 n/pulse |
2420 | Up 95A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0013 n/pulse |
2421 | Up 100A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0008 n/pulse |
2422 | Up 85A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0011 n/pulse |
2423 | Up 80A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.00108 n/pulse |
2425 | Center 0A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0012 n/pulse |
2426 | Down 80A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.00103 n/pulse |
2427 | Up 90A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.00093 n/pulse |
2428 | Up 70A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0021 n/pulse |
2429 | Up 50A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.00086 n/pulse |
2430 | Up 60A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.00115 n/pulse |
2431 | Up 75A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0015 n/pulse |
2432 | Up 70A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0010 n/pulse |
2433 | Up 80A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0012 n/pulse |
2434 | Up 70A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0012 n/pulse |
2435 | Up 90A | In | Open | Yes | Up 2 mm | DU plate | Same.
R(beam down) = 0.0011 n/pulse |
2438 | Up 90A | In | Open | Yes | Up 2 mm | DU plate | Beam spot on the flag was readjusted
R(beam down) = 0.00 n/pulse |
... | A lot was done (see lab books) and after putting additional upstream and downstream collimator, finally some production runs: | ||||||
2450 | Up 2 mm | In | Open | Yes | Out | DU plate | Additional downstream collimator in. Additional upstream collimator in
R(beam down) = 0.000031 n/pulse |
2451 | Up 2 mm | In | Open | Yes | Up 2 mm | DU plate | Same additional radiator. Lost beam
R(beam down) = 0.00027 n/pulse |
2452 | Up 2 mm | In | Open | Yes | Up 2 mm | DU plate | Same additional radiator
R(beam down) = 0.000153 n/pulse |
2453 | Down 2 mm | In | Open | Yes | Out | DU plate | Same additional radiator
R(beam down) = 0.0000238 n/pulse |
2454 | Down 2 mm | In | Open | Yes | Down 2 mm | DU plate | Same additional radiator. Lost beam |
2455 | Down 2 mm | In | Open | Yes | Down 2 mm | DU plate | Same additional radiator. Lost beam |
2456 | Down 2 mm | In | Open | Yes | Down 2 mm | DU plate | Same additional radiator
R(beam down) = 0.000187 n/pulse |