Set up like that:

Detector1.png

the distance between PS and n's PMT is abot 50 cm


The voltages, thresholds and widths are as below. Note: I increased my thresholds for PS1 and PS2 from 80 mV up to 100 mV according to my previous calibration threshold line.

PMT voltage, V threshold, mV discr. width, ns
PS1 -1000 -100 50
PS1 -1000 -100 50
n's -1500 -200 10



First let's do the PS1+PS2 coincidence test

counts time counts/sec
PS1 [math]7513\pm[/math] 60 min [math]\pm[/math]
PS2 [math]9036\pm[/math] 60 min [math]\pm[/math]
PS1+PS2 [math]251\pm[/math] 60 min [math](\pm)\cdot 10^{-2}[/math]


Second do the PS1+PS2+n's coincidence test


The ratio of (PS+PS2) rate to (PS+PS2+n's) rate is

[math]\frac{7.7}{4.9} = 1.6[/math]