05/13/2011 coincidence test

From New IAC Wiki
Revision as of 22:02, 13 May 2011 by Shaproma (talk | contribs)
Jump to navigation Jump to search

Go Back

Set up like that:

Detector1.png

the distance between PS and n's PMT is abot 80 cm


The voltages and thresholds are as below. Note: I increased my thresholds for PS1 and PS2 from 80 mV up to 100 mV according to mu previous calibration threshold line.

PMT voltage, V threshold, mV discr. width, ns
PS1 -1500 -80 100
PS1 -1500 -80 100
n's -1500 -200 10



Let's do first the coincidence test PS1+PS2

counts time counts/sec
PS1 [math]2823\pm53.1[/math] 20 min [math]2.35\pm0.04[/math]
PS2 [math]3091\pm55.6[/math] 20 min [math]2.58\pm0.05[/math]
PS1+PS2 [math]93\pm9.6[/math] 20 min [math](7.7\pm0.8)\cdot 10^{-2}[/math]


The scope picture of PS1+PS2 coincidence event like:

Cosmic coinc PS1 PS2.png