Accelerator Tuning
Good Tune Used for good Scan
By Dr. Kim
Solenoid 1 |
6.8 A
|
Solenoid 2 |
10.4 A
|
Gun Ver |
-0.2 A
|
Gun Hor |
+0.4 A
|
Output Hor |
-1.4A
|
Output Ver |
-0.5 A
|
Gun HV |
+9.75 (Knob Setting)
|
Gun Grid Voltage |
5.25 (Knob Setting)
|
RF frequency |
2855.816 MHz
|
Modulator HV Power Supply |
4.42 (Knob Setting)
|
RF macro Pulse Length (FWHM) |
200 ns
|
Peak Current on FC |
37.2 mAmps
|
Scope on FC |
|
e- Beam Energy |
14 MeV
|
Calibration
image |
OTR image |
cal_h (mm/px) |
cal_v (mm/px)
|
|
|
0.04308 |
0.04204
|
|
|
0.04320 |
0.04228
|
|
|
0.04349 |
0.04181
|
|
|
0.04323 |
0.04196
|
|
|
0.04337 |
0.04212
|
|
|
mean (mm/px) |
mean (mm/px)
|
|
|
[math] 0.04327 \pm 0.00016 [/math] |
[math] 0.04204 \pm 0.00018 [/math]
|
Results
Q1
42 mA, Positive Current, X projection
emit=0.375 +- 0.001 mm*mrad, emit_norm=10.263 +- 0.033 mm*mrad
beta=1.250 +- 0.000, alpha=0.936 +-0.001
HRRL_Emittance_Measurements_March14-18-2011