HRRL 03-16-2011

From New IAC Wiki
Jump to navigation Jump to search

Scan

Quad 4

164 mA

HRRL 03 16 2011 Scan Q4 164mA Par Fit X.png

x-projection:

emit=0.755 +- 0.186 mm*mrad, emit_norm=14.776 +- 3.641 mm*mrad

beta=0.412 +- 0.043, alpha=1.496 +-0.169

HRRL 03 16 2011 Scan Q4 164mA Par Fit Y.png

y-projection:

emit=0.855 +- 0.013 mm*mrad, emit_norm=16.733 +- 0.264 mm*mrad

beta=0.507 +- 0.004, alpha=-0.648 +-0.010

80 mA

HRRL 03 16 2011 Scan Q4 80mA Par Fit X.png


HRRL 03 16 2011 Scan Q4 80mA Par Fit Y.png


40 mA

HRRL 03 16 2011 Scan Q4 40mA Par Fit X.png


HRRL 03 16 2011 Scan Q4 40mA Par Fit Y.png


20 mA

HRRL 03 16 2011 Scan Q4 20mA Par Fit X.png


363 px

Energy Scan

Dipole Current Beam Energy Using Dipole Map Observed FC current
(mA) MeV pV*s


HRRL_Emittance_Measurements_March14-18-2011